Evaluation of low-pressure gas chromatography linked to ion-trap tandem mass spectrometry for the fast trace analysis of multiclass pesticide residues

被引:32
作者
González-Rodríguez, MJ [1 ]
Garrido-Frenich, A [1 ]
Arrebola, FJ [1 ]
Martínez-Vidal, JL [1 ]
机构
[1] Univ Almeria, Dept Analyt Chem, Almeria 04120, Spain
关键词
D O I
10.1002/rcm.707
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid multiresidue method for the analysis of 72 pesticides has been developed using a single injection with low-pressure gas chromatography/tandem mass spectrometry (LP-GC/MS/MS). The LP-GC/MS/MS method used a short capillary column of 10 m x 0.53 mm i.d. x 0.25 mum film thickness coupled with a 0.6 m x 0.10 mm i.d. restriction at the inlet end. Optimal LP-GC conditions were determined which achieved the fastest separation in MS/MS detection mode. Also MS/MS conditions were optimized in order to increase sensitivity and selectivity. The analytical parameters of the LP-GC/MS/MS method were compared with those obtained by GC/MS/MS using a conventional capillary column (30 m x 0.25 mm i.d. x 0.25 mum film thickness). Better precision and sensitivity values were obtained with the LP-GC/MS/MS approach. The limits of detection (LOD) of the compounds ranged from 0.1 to 14.1 mug L-1 for LP-GC/MS/MS, lower than those obtained for conventional GC/MS/MS that ranged from 0.1 to 17.5 mug L-1. The peak widths obtained with the short column in LP-GC are similar to those obtained using conventional capillary GC columns, and the peaks can be successfully identified by MS/MS detection with the conventional scan speed of ion-trap instruments. In addition, the analysis time was significantly reduced with LP-GC/MS/MS (32 min) versus GC/MS/MS (72 min), allowing the number of samples analyzed per day in a routine laboratory to be doubled. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1216 / 1224
页数:9
相关论文
共 40 条
[11]  
de Zeeuw J, 2000, HRC-J HIGH RES CHROM, V23, P677
[12]  
Desty D. H, 1962, GAS CHROMATOGRAPHY, P105
[13]  
DESTY DH, 1965, ADV CHROMATOGR, V1, P199
[14]  
ES AV, 1992, HIGH SPEED NARROW BO
[15]  
Frenich AG, 2000, J MASS SPECTROM, V35, P967, DOI 10.1002/1096-9888(200008)35:8<967::AID-JMS24>3.0.CO
[16]  
2-V
[17]   Comparison of gas chromatography with NPD, MS, and tandem MS-MS in the multiresidue analysis of pesticides in environmental waters [J].
Frenich, AG ;
Vidal, JLM ;
Espada, MCP ;
García, MDG ;
Arrebola, FJ .
CHROMATOGRAPHIA, 2000, 52 (9-10) :614-620
[18]   THEORY OF MINIMUM TIME OPERATION IN GAS CHROMATOGRAPHY [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1962, 34 (03) :314-&
[19]   THEORETICAL AND PRACTICAL ASPECTS OF SHORT OPEN TUBULAR COLUMNS AT SUBAMBIENT PRESSURES IN GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HAIL, ME ;
YOST, RA .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2402-2410
[20]   Purge-and-trap gas chromatography-mass spectrometry in the analysis of volatile organochlorine compounds in water [J].
Lee, MR ;
Lee, JS ;
Hsiang, WS ;
Chen, CM .
JOURNAL OF CHROMATOGRAPHY A, 1997, 775 (1-2) :267-274