Evaluation of low-pressure gas chromatography linked to ion-trap tandem mass spectrometry for the fast trace analysis of multiclass pesticide residues

被引:32
作者
González-Rodríguez, MJ [1 ]
Garrido-Frenich, A [1 ]
Arrebola, FJ [1 ]
Martínez-Vidal, JL [1 ]
机构
[1] Univ Almeria, Dept Analyt Chem, Almeria 04120, Spain
关键词
D O I
10.1002/rcm.707
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid multiresidue method for the analysis of 72 pesticides has been developed using a single injection with low-pressure gas chromatography/tandem mass spectrometry (LP-GC/MS/MS). The LP-GC/MS/MS method used a short capillary column of 10 m x 0.53 mm i.d. x 0.25 mum film thickness coupled with a 0.6 m x 0.10 mm i.d. restriction at the inlet end. Optimal LP-GC conditions were determined which achieved the fastest separation in MS/MS detection mode. Also MS/MS conditions were optimized in order to increase sensitivity and selectivity. The analytical parameters of the LP-GC/MS/MS method were compared with those obtained by GC/MS/MS using a conventional capillary column (30 m x 0.25 mm i.d. x 0.25 mum film thickness). Better precision and sensitivity values were obtained with the LP-GC/MS/MS approach. The limits of detection (LOD) of the compounds ranged from 0.1 to 14.1 mug L-1 for LP-GC/MS/MS, lower than those obtained for conventional GC/MS/MS that ranged from 0.1 to 17.5 mug L-1. The peak widths obtained with the short column in LP-GC are similar to those obtained using conventional capillary GC columns, and the peaks can be successfully identified by MS/MS detection with the conventional scan speed of ion-trap instruments. In addition, the analysis time was significantly reduced with LP-GC/MS/MS (32 min) versus GC/MS/MS (72 min), allowing the number of samples analyzed per day in a routine laboratory to be doubled. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1216 / 1224
页数:9
相关论文
共 40 条
[1]   Megabore versus microbore as the optimal column for fast gas chromatography mass spectrometry [J].
Amirav, A ;
Tzanani, N ;
Wainhaus, SB ;
Dagan, S .
EUROPEAN MASS SPECTROMETRY, 1998, 4 (01) :7-13
[2]   Conventional inner diameter short capillary columns: an approach to speeding up gas chromatographic analysis of medium complexity samples [J].
Bicchi, C ;
Brunelli, C ;
Galli, M ;
Sironi, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 931 (1-2) :129-140
[3]  
Blumberg LM, 1997, HRC-J HIGH RES CHROM, V20, P679
[4]  
Blumberg LM, 1997, HRC-J HIGH RES CHROM, V20, P597
[5]  
Blumberg LM, 1999, HRC-J HIGH RES CHROM, V22, P403
[6]  
BUSH KL, 1998, MASS SPECTROMETRY MA
[7]   Strategies for speed optimisation in gas chromatography: an overview [J].
Cramers, CA ;
Leclercq, PA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :3-13
[8]   INCREASED SPEED OF ANALYSIS IN DIRECTLY COUPLED GAS CHROMATOGRAPHY-MASS SPECTROMETRY SYSTEMS - CAPILLARY COLUMNS AT SUB-ATMOSPHERIC OUTLET PRESSURES [J].
CRAMERS, CA ;
SCHERPENZEEL, GJ ;
LECLERCQ, PA .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :207-216
[9]   High-speed gas chromatography: an overview of various concepts [J].
Cramers, CA ;
Janssen, HG ;
van Deursen, MM ;
Leclercq, PA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :315-329
[10]   Instrumentation and applications of fast high-resolution capillary gas chromatography [J].
David, F ;
Gere, DR ;
Scanlan, F ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :309-319