Complications of locking and non-locking plate systems in mandibular fractures

被引:5
作者
Batbayar, E-O [1 ,2 ]
Dijkstra, P. U. [1 ,3 ]
Bos, R. R. M. [1 ]
van Minnen, B. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Oral & Maxillofacial Surg, POB 30-001, NL-9700 RB Groningen, Netherlands
[2] Mongolian Natl Univ Med Sci, Sch Dent, Dept Oral & Maxillofacial Surg, Ulaanbaatar, Mongolia
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Rehabil, Groningen, Netherlands
关键词
mandibular fractures; bone plates; locking plate; conventional plate; postoperative complications; meta-analysis; 2.0 MM STANDARD; MINIPLATE OSTEOSYNTHESIS; ANGLE FRACTURES; BITE FORCE; FIXATION; MANAGEMENT; METAANALYSIS; OUTCOMES;
D O I
10.1016/j.ijom.2019.02.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This systematic review and meta-analysis was performed to critically assess the methodological quality of the existing systematic reviews, and to evaluate the postoperative complications of the mandibular fractures treated with locking and non-locking plate systems. An electronic search was conducted in PubMed, Embase, Web of Science, Cochrane library's electronic databases and grey literate using a combination of Medical Subject Heading terms and key words, until September 2018. No restrictions were applied to the search strategy. In total, three relevant systematic reviews were included, and the quality of these studies was low. A total of 33 studies (20 randomized studies and 13 non-randomized studies) were included in this systematic review, and 16 of them were included in meta-analysis. Most of the included randomized studies had an unclear risk of bias (Cochrane Collaboration); the quality of non-randomized studies ranged between 6 and 17 (Methodological Index for Non-Randomized Studies MINORS). Based on the results of our meta-analysis, we conclude that locking plates are superior only with respect to the need for mandibulomaxillary fixation (MMF) in the early postoperative period.
引用
收藏
页码:1213 / 1226
页数:14
相关论文
共 56 条
[21]   Clinical outcomes of three different types of hardware for the treatment of mandibular angle fractures: a comparative retrospective study [J].
Elsayed, S. A. ;
Mohamed, F. I. ;
Khalifa, G. A. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (10) :1260-1267
[22]   Analysis of complications in fractures of the mandibular angle - a study with finite element computation and evaluation of data of 277 patients [J].
Feller, KU ;
Schneider, M ;
Hlawitschka, M ;
Pfeifer, G ;
Lauer, G ;
Eckelt, U .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2003, 31 (05) :290-295
[23]   Maxillofacial trauma in the elderly [J].
Gerbino, G ;
Roccia, F ;
De Gioanni, PP ;
Berrone, S .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (07) :777-782
[24]   Bite Force Evaluation of Conventional Plating System Versus Locking Plating System for Mandibular Fracture [J].
Giri K.Y. ;
Sahu P. ;
Rastogi S. ;
Dandriyal R. ;
Mall S. ;
Singh A.P. ;
Indra B N.P. ;
Pratap Singh H. .
Journal of Maxillofacial and Oral Surgery, 2015, 14 (4) :972-978
[25]  
Goyal M, 2011, J MAXILLOFAC ORAL SU, V10, P316, DOI 10.1007/s12663-011-0242-9
[26]   Outcomes of Mandible Fracture Treatment at an Academic Tertiary Hospital: A 5-Year Analysis [J].
Gutta, Rajesh ;
Tracy, Kyle ;
Johnson, Christopher ;
James, Laura E. ;
Krishnan, Deepak G. ;
Marciani, Robert D. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 72 (03) :550-558
[27]   Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates [J].
Haug, RH ;
Street, CC ;
Goltz, M .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (11) :1319-1326
[28]   Assessing the quality of reports of randomized clinical trials: Is blinding necessary? [J].
Jadad, AR ;
Moore, RA ;
Carroll, D ;
Jenkinson, C ;
Reynolds, DJM ;
Gavaghan, DJ ;
McQuay, HJ .
CONTROLLED CLINICAL TRIALS, 1996, 17 (01) :1-12
[29]   Management of mandibular interforaminal fractures using 3 dimensional locking and standard titanium miniplates - A comparative preliminary report of 10 cases [J].
Jain, Manoj Kumar ;
Sankar, K. ;
Ramesh, C. ;
Bhatta, Ramakrishna .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) :E475-E478
[30]   A comparison of three treatment methods for fractures of the mandibular angle [J].
Kim, M-Y. ;
Kim, C-H. ;
Han, S-J. ;
Lee, J-H. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (07) :878-883