Determination of sulfur dioxide based on a silver dispersed functional self-assembled electrochemical sensor

被引:29
作者
Shankaran, DR [1 ]
Uehera, N [1 ]
Kato, T [1 ]
机构
[1] Utsunomiya Univ, Satellite Venture Business Lab, Dept Appl Chem, Utsunomiya, Tochigi 3218588, Japan
关键词
metal dispersed self-assembly; (3-mercaptopropyl)trimethoxysilane; silver; sulfur dioxide; electrocatalysis;
D O I
10.1016/S0925-4005(02)00304-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and simple amperometric sensor for sulfur dioxide (SO2) has been constructed based on the self-assembly of (3-mercaptopropyl)-trimetboxysilane (MPS) over a glassy carbon (GC) electrode followed by the complexation with silver. The silver dispersed onto the self-assembled surface exhibited excellent electrocatalytic activity for the determination of sulfur dioxide at a reduced potential (+0.3 V) with good sensitivity in a wide concentration range from 0.6 to 88 ppm with a correlation coefficient of 0.9989. The proposed sensor is easy to fabricate and has the advantages of good stability, reproducibility and rapid response. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:442 / 447
页数:6
相关论文
共 14 条
  • [1] Solid-state amperometric sensors for gas phase analytes: A review of recent advances
    Alber, KS
    Cox, JA
    Kulesza, PJ
    [J]. ELECTROANALYSIS, 1997, 9 (02) : 97 - 101
  • [2] Determination of sulfur dioxide in wines by gas-diffusion flow injection analysis utilizing modified electrodes with electrostatically assembled films of tetraruthenated porphyrin
    Azevedo, CMN
    Araki, K
    Toma, HE
    Angnes, L
    [J]. ANALYTICA CHIMICA ACTA, 1999, 387 (02) : 175 - 180
  • [3] Bilitewski U., 2000, Biosensors in Environmental Monitoring
  • [4] Self-assembled monolayers: a versatile tool for the formulation of bio-surfaces
    Ferretti, S
    Paynter, S
    Russell, DA
    Sapsford, KE
    Richardson, DJ
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (09) : 530 - 540
  • [5] The application of alkanethiol self-assembled monolayers to enzyme electrodes
    Gooding, JJ
    Hibbert, DB
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (08) : 525 - 533
  • [6] Electrochemical sensor for the detection of SO2 in the low-ppb range
    Hodgson, AWE
    Jacquinot, P
    Hauser, PC
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (14) : 2831 - 2837
  • [7] Shankaran DR, 1999, SENSOR ACTUAT B-CHEM, V55, P191, DOI 10.1016/S0925-4005(99)00053-2
  • [8] Shankaran DR, 2002, ELECTROANAL, V14, P704, DOI 10.1002/1521-4109(200205)14:10<704::AID-ELAN704>3.0.CO
  • [9] 2-#
  • [10] The study of PVP/Pd/IrO2 modified sensor for amperometric determination of sulfur dioxide
    Shi, GY
    Luo, M
    Xue, J
    Xian, YZ
    Jin, LT
    Jin, JY
    [J]. TALANTA, 2001, 55 (02) : 241 - 247