Common-Path Dual-Comb Spectroscopy Using a Single Electro-Optic Modulator

被引:19
作者
Soriano-Amat, Miguel [1 ]
Soto, Marcelo A. [2 ]
Duran, Vicente [3 ]
Martins, Hugo F. [4 ]
Martin-Lopez, Sonia [1 ]
Gonzalez-Herraez, Miguel [1 ]
Fernandez-Ruiz, Maria R. [1 ]
机构
[1] Univ Alcala, Dept Elect, Edificio Politecn Super, Alcala De Henares 28805, Spain
[2] Univ Tecn Federico Santa Maria, Dept Elect Engn, Valparaiso 2390123, Chile
[3] Univ Jaume 1, GROC UJI, Inst New Imaging Technol, Castellon de La Plana 120071, Spain
[4] IO CSIC, Inst Opt Daza de Valdes, Madrid 28006, Spain
关键词
Optical interferometry; Optical filters; Optical saturation; Frequency modulation; Electrooptic modulators; Arbitrary waveform generation; brillouin scattering; dual comb spectroscopy; optical frequency combs; OPTICAL FREQUENCY COMBS; INTERFEROMETRY; GENERATION; SOLITONS;
D O I
10.1109/JLT.2020.2998372
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dual frequency comb (DFC) spectroscopy using electro-optic comb generators stands out for its flexibility, easy implementation, and low cost. Typically, two combs with different line spacing are generated from a common laser using independent electro-optic comb generators. This approach minimizes the impact of laser phase noise; however, the distinct paths followed by the two combs ultimately limit the attainable signal-to-noise ratio and long-term stability of the system. In this work, a common-path DFC is generated using a single modulator driven by an arbitrary waveform generator, thus enabling a remarkable increase of the system stability (up to 0.8 s of integration time) while maintaining high flexibility. The proposed technique is experimentally validated by implementing a dual frequency comb with 3000 lines, covering an optical bandwidth of 4.5 GHz, and demonstrating an optical-to-radiofrequency compression factor of 7500. Our system is able to measure extremely narrowband optical features (in the MHz range) with an accuracy only limited by the master laser stability.
引用
收藏
页码:5107 / 5115
页数:9
相关论文
共 33 条
[1]   A digitally generated ultrafine optical frequency comb for spectral measurements with 0.01-pm resolution and 0.7-μs response time [J].
Bao, Yuan ;
Yi, Xingwen ;
Li, Zhaohui ;
Chen, Qingming ;
Li, Jianping ;
Fan, Xudong ;
Zhang, Xuming .
LIGHT-SCIENCE & APPLICATIONS, 2015, 4 :e300-e300
[2]   Dual-comb interferometry via repetition rate switching of a single frequency comb [J].
Carlson, David R. ;
Hickstein, Daniel D. ;
Cole, Daniel C. ;
Diddams, Scott A. ;
Papp, Scott B. .
OPTICS LETTERS, 2018, 43 (15) :3614-3617
[3]   Rapid and precise absolute distance measurements at long range [J].
Coddington, I. ;
Swann, W. C. ;
Nenadovic, L. ;
Newbury, N. R. .
NATURE PHOTONICS, 2009, 3 (06) :351-356
[4]   Coherent multiheterodyne spectroscopy using stabilized optical frequency combs [J].
Coddington, Ian ;
Swann, William C. ;
Newbury, Nathan R. .
PHYSICAL REVIEW LETTERS, 2008, 100 (01)
[5]  
Coddington I, 2016, OPTICA, V3, P414, DOI [10.1364/optica.3.000414, 10.1364/OPTICA.3.000414]
[6]   Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb [J].
Diddams, Scott A. ;
Hollberg, Leo ;
Mbele, Vela .
NATURE, 2007, 445 (7128) :627-630
[7]   Bidirectional frequency-shifting loop for dual-comb spectroscopy [J].
Duran, Vicente ;
Djevarhidjian, Leo ;
Guillet de Chatellus, Hugues .
OPTICS LETTERS, 2019, 44 (15) :3789-3792
[8]   Coherent multi-heterodyne spectroscopy using acousto-optic frequency combs [J].
Duran, Vicente ;
Schnebelin, Come ;
De Chatellus, Hugues Guillet .
OPTICS EXPRESS, 2018, 26 (11) :13800-13809
[9]   Electro-optic dual-comb interferometry over 40 nm bandwidth [J].
Duran, Vicente ;
Andrekson, Peter A. ;
Torres-Company, Victor .
OPTICS LETTERS, 2016, 41 (18) :4190-4193
[10]   Ultrafast electrooptic dual-comb interferometry [J].
Duran, Vicente ;
Tainta, Santiago ;
Torres-Company, Victor .
OPTICS EXPRESS, 2015, 23 (23) :30557-30569