The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of Diseases

被引:420
作者
Khalil, Sami F. [1 ,2 ,3 ]
Mohktar, Mas S. [1 ,2 ]
Ibrahim, Fatimah [1 ,2 ]
机构
[1] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Engn, CIME, Kuala Lumpur 50603, Malaysia
[3] Sudan Univ Sci & Technol, Coll Engn, Dept Biomed Engn, Khartoum 407, Sudan
关键词
bioimpedance analysis; body composition; clinical status monitoring; diseases diagnostic and prediction; BIOELECTRICAL-IMPEDANCE ANALYSIS; TOTAL-BODY WATER; FAT-FREE MASS; OBSTRUCTIVE PULMONARY-DISEASE; ETHNIC-POPULATION GROUPS; SKELETAL-MUSCLE MASS; VECTOR ANALYSIS BIVA; WHOLE-BODY; HEMODIALYSIS-PATIENTS; CELL MASS;
D O I
10.3390/s140610895
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance vector analysis and the real time bioimpedance analysis systems. Commonly used prediction equations for body composition assessment and influence of anthropometric measurements, gender, ethnic groups, postures, measurements protocols and electrode artifacts in estimated values are also discussed. In addition, this paper also contributes to the deliberations of bioimpedance analysis assessment of abnormal loss in lean body mass and unbalanced shift in body fluids and to the summary of diagnostic usage in different kinds of conditions such as cardiac, pulmonary, renal, and neural and infection diseases.
引用
收藏
页码:10895 / 10928
页数:34
相关论文
共 146 条
[1]   Bioelectrical impedance parameters in critically ill children: Importance of reactance and resistance [J].
Almeida Azevedo, Zina Maria ;
Batalha Cox Moore, Daniella Campelo ;
Alves de Matos, Flavia Aparecida ;
Fonseca, Vania Matos ;
Marques Peixoto, Maria Virginia ;
Gaspar-Elsas, Maria Ignez C. ;
Santinoni, Erika ;
dos Anjos, Luiz Antonio ;
Ramos, Eloane Goncalves .
CLINICAL NUTRITION, 2013, 32 (05) :824-829
[2]  
[Anonymous], 1996, Am J Clin Nutr, V64, p524S, DOI 10.1093/ajcn/64.3.524S
[3]  
Atilano X, 2012, KIDNEY RES CLIN PRAC, V31, pA17
[4]   Cole Equation and Parameter Estimation from Electrical Bioimpedance Spectroscopy Measurements - A Comparative Study [J].
Ayllon, David ;
Seoane, Fernando ;
Gil-Pita, Roberto .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :3779-3782
[5]   Body-water compartments measured by bio-electrical impedance spectroscopy in patients with chronic obstructive pulmonary disease [J].
Baarends, EM ;
Lichtenbelt, WDV ;
Wouters, EFM ;
Schols, AMWJ .
CLINICAL NUTRITION, 1998, 17 (01) :15-22
[6]   BIOELECTRIC IMPEDANCE PHASE-ANGLE AND BODY-COMPOSITION [J].
BAUMGARTNER, RN ;
CHUMLEA, WC ;
ROCHE, AF .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 48 (01) :16-23
[7]   Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans [J].
Bracco, D ;
Thiebaud, D ;
Chiolero, RL ;
Landry, M ;
Burckhardt, P ;
Schutz, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) :2580-2587
[8]   Bedside determination of fluid accumulation after cardiac surgery using segmental bioelectrical impedance [J].
Bracco, D ;
Revelly, JP ;
Berger, MM ;
Chioléro, RL .
CRITICAL CARE MEDICINE, 1998, 26 (06) :1065-1070
[9]  
Buchholz Andrea C, 2004, Nutr Clin Pract, V19, P433, DOI 10.1177/0115426504019005433
[10]   Influence of electrode mismatch on Cole parameter estimation from Total Right Side Electrical Bioimpedance Spectroscopy measurements [J].
Buendia, Ruben ;
Bogonez-Franco, Paco ;
Nescolarde, Lexa ;
Seoane, Fernando .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (07) :1024-1028