Enhancing power system state estimation by incorporating equality constraints of voltage dependent loads and zero injections

被引:3
作者
Kabiri, Mehdi [1 ]
Amjady, Nima [1 ]
Shafie-khah, Miadreza [2 ]
Catalao, Joao P. S. [2 ,3 ,4 ,5 ]
机构
[1] Semnan Univ, Elect Engn Dept, Semnan, Iran
[2] Univ Beira Interior, C MAST, P-6201001 Covilha, Portugal
[3] Univ Porto, INESC TEC, P-4200465 Porto, Portugal
[4] Univ Porto, Fac Engn, P-4200465 Porto, Portugal
[5] Univ Lisbon, Inst Super Tecn, INESC ID, P-1049001 Lisbon, Portugal
基金
欧盟第七框架计划;
关键词
Constrained weighted least squares; Energy management system; Voltage dependent load model; TOPOLOGY ERROR IDENTIFICATION; PARAMETER;
D O I
10.1016/j.ijepes.2018.02.016
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new state estimation (SE) method including equality constraints to model voltage dependent loads and zero injections. Formulation of conventional SE, assuming simple constant power model for the system's loads, is modified to incorporate voltage dependent load models. Assuming reliable load models and zero injections, it is analytically proved that modeling the equality constraints leads to better SE accuracy. To numerically validate the analytical findings, the proposed SE method is implemented on the IEEE 118-bus test system and the large-scale real-world Iran's power system, and its obtained results are compared with the results of conventional SE. Also, it is shown that considering voltage dependent load model in SE formulation leads to better performance of bad data detection. Moreover, it is illustrated that the accuracy of the proposed SE has low sensitivity to load model identification error.
引用
收藏
页码:659 / 671
页数:13
相关论文
共 29 条
[1]  
ABB Network Control Ltd, 1995, PN40 OP MAN, V2
[2]  
Abur A., 2004, POWER SYSTEM STATE E
[3]   Online Tracking of Voltage-Dependent Load Parameters Using ULTC Created Disturbances [J].
Arefifar, Seyed Ali ;
Xu, Wilsun .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (01) :130-139
[4]  
Billinton R, 2013, Reliability assessment of electrical power systems using Monte Carlo methods
[5]   Multiple Bad Data Identification Considering Measurement Dependencies [J].
Caro, Eduardo ;
Conejo, Antonio J. ;
Minguez, Roberto ;
Zima, Marija ;
Andersson, Goeran .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (04) :1953-1961
[6]   Power System State Estimation Considering Measurement Dependencies [J].
Caro, Eduardo ;
Conejo, Antonio J. ;
Minguez, Roberto .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (04) :1875-1885
[7]   LTS-Based Robust Hybrid SE Integrating Correlation [J].
Chakhchoukh, Yacine ;
Vittal, Vijay ;
Heydt, Gerald T. ;
Ishii, Hideaki .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (04) :3127-3135
[8]   Topology error identification using normalized Lagrange multipliers [J].
Clements, KA ;
Costa, AS .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1998, 13 (02) :347-353
[9]  
Eremia Mircea., 2013, HDB ELECT POWER SYST, DOI 10.1002/9781118516072
[10]   LAV Based Robust State Estimation for Systems Measured by PMUs [J].
Goel, Murat ;
Abur, Ali .
IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (04) :1808-1814