Biosensing of glucose in flow injection analysis system based on glucose oxidase-quantum dot modified pencil graphite electrode

被引:47
作者
Saglam, Ozlem [1 ]
Kizilkaya, Bayram [2 ]
Uysal, Huseyin [3 ]
Dilgin, Yusuf [1 ]
机构
[1] Canakkale Onsekiz Mart Univ, Fac Art & Sci, Dept Chem, Canakkale, Turkey
[2] Canakkale Onsekiz Mart Univ, Fac Marine Sci & Technol, Canakkale, Turkey
[3] Canakkale Onsekiz Mart Univ, Fac Art & Sci, Dept Mol Biol & Genet, Canakkale, Turkey
关键词
Glucose oxidase; Quantum dots; Glucose biosensor; Flow injection analysis; Pencil graphite electrode; CDSE/CDS CORE/SHELL NANOCRYSTALS; DIRECT ELECTROCHEMISTRY; ELECTROCATALYTIC OXIDATION; AMPEROMETRIC DETERMINATION; CDS; NANOPARTICLES; PLATFORM; SENSOR; GRAPHENE; IMMOBILIZATION;
D O I
10.1016/j.talanta.2015.09.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric glucose biosensor was proposed in flow injection analysis (FIA) system using glucose oxidase (GOD) and Quantum dot (ZnS-CdS) modified Pencil Graphite Electrode (PGE). After ZnS-CdS film was electrochemically deposited onto PGE surface, GOD was immobilized on the surface of ZnS-CdS/PGE through crosslinking with chitosan (CT). A pair of well-defined reversible redox peak of GOD was observed at GOD/CT/ZnS-CdS/PGE based on enzyme electrode by direct electron transfer between the protein and electrode. Further, obtained GOD/CT/ZnS-CdS/PGE offers a disposable, low cost, selective and sensitive electrochemical biosensing of glucose in FIA system based on the decrease of the electrocatalytic response of the reduced form of GOD to dissolved oxygen. Under optimum conditions (flow rate, 1.3 mL min(-1); transmission tubing length, 10 cm; injection volume, 100 mu L; and constant applied potential, -500 mV vs. Ag/AgCl), the proposed method displayed a linear response to glucose in the range of 0.01-1.0 mM with detection limit of 3.0 mu M. The results obtained from this study would provide the basis for further development of the biosensing using PGE based FIA systems. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:315 / 321
页数:7
相关论文
共 41 条
[1]   Molybdenum oxide/platinum modified glassy carbon electrode: A novel electrocatalytic platform for the monitoring of electrochemical reduction of oxygen and its biosensing applications [J].
Cakar, Irem ;
Ozdokur, K. Volkan ;
Demir, Bilal ;
Yavuz, Elvin ;
Demirkol, Dilek Odaci ;
Kocak, Suleyman ;
Timur, Suna ;
Ertas, Fatma Nil .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 :331-336
[2]   A bio-electrochemical sensing platform for glucose based on irreversible, non-covalent pi-pi functionalization of graphene produced via a novel, green synthesis method [J].
Chia, Joanna Su Yuin ;
Tan, Michelle T. T. ;
Khiew, Poi Sim ;
Chin, Jit Kai ;
Siong, Chiu Wee .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 :558-565
[3]   Sensitive Voltammetric Determination of Niclosamide at a disposable pencil graphite electrode [J].
Dede, Eda ;
Saglam, Ozlem ;
Dilgin, Yusuf .
ELECTROCHIMICA ACTA, 2014, 127 :20-26
[4]   Photoelectrochemical glucose biosensor in flow injection analysis system based on glucose dehydrogenase immobilized on poly-hematoxylin modified glassy carbon electrode [J].
Dilgin, Didem Giray ;
Gokcel, H. Ismet .
ANALYTICAL METHODS, 2015, 7 (03) :990-999
[5]   Electrocatalytic Oxidation of NADH Using a Pencil Graphite Electrode Modified with Hematoxylin [J].
Dilgin, Yusuf ;
Ertek, Bensu ;
Kizilkaya, Bayram ;
Dilgin, Didem Giray ;
Gokcel, H. Ismet .
SCIENCE OF ADVANCED MATERIALS, 2012, 4 (09) :920-927
[6]   Amperometric determination of sulfide based on its electrocatalytic oxidation at a pencil graphite electrode modified with quercetin [J].
Dilgin, Yusuf ;
Kizilkaya, Bayram ;
Ertek, Bensu ;
Erena, Nuri ;
Dilgin, Didem Giray .
TALANTA, 2012, 89 :490-495
[7]   ZnS nanoparticles electrodeposited onto ITO electrode as a platform for fabrication of enzyme-based biosensors of glucose [J].
Du, Jian ;
Yu, Xiuping ;
Wu, Ying ;
Di, Junwei .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (04) :2031-2036
[8]   Comparison of the direct electrochemistry of glucose oxidase immobilized on the surface of Au, CdS and ZnS nanostructures [J].
Du, Jian ;
Yu, Xiuping ;
Di, Junwei .
BIOSENSORS & BIOELECTRONICS, 2012, 37 (01) :88-93
[9]   An ultrasensitive electrochemical biosensor for glucose using CdTe-CdS core-shell quantum dot as ultrafast electron transfer relay between graphene-gold nanocomposite and gold nanoparticle [J].
Gu Zhiguo ;
Yang Shuping ;
Li Zaijun ;
Sun Xiulan ;
Wang Guangli ;
Fang Yinjun ;
Liu Junkang .
ELECTROCHIMICA ACTA, 2011, 56 (25) :9162-9167
[10]  
Hansen EH, 1996, J MOL RECOGNIT, V9, P316, DOI 10.1002/(SICI)1099-1352(199634/12)9:5/6<316::AID-JMR276>3.0.CO