A large area CCD X-ray detector for exotic atom spectroscopy

被引:41
作者
Nelms, N [1 ]
Anagnostopoulos, DF
Ayranov, O
Borchert, G
Egger, JP
Gotta, D
Hennebach, M
Indelicato, P
Leoni, B
Liu, YW
Manil, B
Simons, LM
Wells, A
机构
[1] Univ Leicester, Dept Phys & Astron, Space Res Ctr, Leicester LE1 7RH, Leics, England
[2] Univ Paris 06, Lab Kastler Brossel, F-75252 Paris, France
[3] Univ Neuchatel, Inst Phys, CH-2000 Neuchatel, Switzerland
[4] Forschungszentrum Julich, Inst Kernphys, D-5170 Julich, Germany
[5] Paul Scherrer Inst, Villigen, Switzerland
[6] Univ Ioannina, Dept Mat Sci & Technol, GR-45110 Ioannina, Greece
关键词
CCD; X-ray detector; exotic atoms; X-ray spectroscopy;
D O I
10.1016/S0168-9002(01)02051-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A large area, position and energy sensitive detector has been developed to study the characteristic X-radiation of exotic atoms in the few keV range. The detector, built up from an array of six high-resistivity CCDs, is used as the focal plane of a reflection-type crystal spectrometer. A large detection area is necessary because of the need to detect simultaneously two or more lines close in energy as well as broad structures like fluorescence X-rays from electronic atoms. The fine pixel structure provides accurate determination of the X-ray line position while the excellent background rejection capabilities of the CCD, using both energy and topographical discrimination. are essential in the high background environment of a particle accelerator. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:419 / 431
页数:13
相关论文
共 17 条
[1]  
BOUCARD S, 1998, COMMUNICATION
[2]   X-ray multi-mirror mission - An overview [J].
Eggel, DLH ;
Laine, R ;
Peacock, A .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 :326-337
[3]  
Groom DE, 2000, EUR PHYS J C, V15, P1
[4]   The MOS CCPs for the EPIC on XMM [J].
Holland, AD ;
Turner, MJL ;
Abbey, AF ;
Pool, P .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 :414-420
[5]  
HOLLAND AD, 1990, THESIS LEICESTER U, P40
[6]   K alpha(1,2) and K beta(1,3) x-ray emission lines of the 3d transitions metals [J].
Holzer, G ;
Fritsch, M ;
Deutsch, M ;
Hartwig, J ;
Forster, E .
PHYSICAL REVIEW A, 1997, 56 (06) :4554-4568
[7]   NOISE-REDUCTION TECHNIQUES FOR CCD IMAGE SENSORS [J].
HOPKINSON, GR ;
LUMB, DH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (11) :1214-1222
[8]   RESPONSE OF A CORRELATED DOUBLE SAMPLING CIRCUIT TO 1-F NOISE [J].
KANSY, RJ .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1980, 15 (03) :373-375
[9]   A new determination of the mass of the charged pion [J].
Lenz, S ;
Borchert, G ;
Gorke, H ;
Gotta, D ;
Siems, T ;
Anagnostopoulos, DF ;
Augsburger, M ;
Chatellard, D ;
Egger, JP ;
Belmiloud, D ;
El-Khoury, P ;
Indelicato, P ;
Daum, M ;
Hauser, P ;
Kirch, K ;
Simons, LM .
PHYSICS LETTERS B, 1998, 416 (1-2) :50-55
[10]   MODELING THE X-RAY RESPONSE OF CHARGE-COUPLED-DEVICES [J].
MCCARTHY, KJ ;
OWENS, A ;
HOLLAND, AD ;
WELLS, AA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 362 (2-3) :538-546