A non-invasive method for in vivo skin volatile compounds sampling

被引:76
作者
Jiang, Ruifen [1 ]
Cudjoe, Erasmus [1 ]
Bojko, Barbara [1 ]
Abaffy, Tatjana [2 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Univ Miami, Dept Mol & Cellular Pharmacol, Miami, FL 33136 USA
关键词
Thin film microextraction (TFME); Skin sampling; Skin emissions; Solid phase microextraction (SPME); SORPTIVE TAPE EXTRACTION; MOSQUITO AEDES-AEGYPTI; ORGANIC-COMPOUNDS; SPME-GC/MS; IDENTIFICATION; EMANATIONS; ACETONE; SPECTROMETRY; ATTRACTANTS; METABOLISM;
D O I
10.1016/j.aca.2013.09.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of volatile organic compounds (VOCs) emanating from human skin presents great potential for skin disease diagnosis. These compounds are emitted at very low concentrations. Thus, the sampling preparation step needs to be implemented before gas chromatography-mass spectrometry (GC-MS) analysis. In this work, a simple, non-invasive headspace sampling method for volatile compounds emanating from human skin is presented, using thin film as the extraction phase format. The proposed method was evaluated in terms of reproducibility, membrane size, extraction mode and storage conditions. First, the in vial sampling showed an intra- and inter-membrane RSD% less than 9.8% and 8.2%, respectively, which demonstrated that this home-made skin volatiles sampling device was highly reproducible with regard to intra-, inter-membrane sampling. The in vivo sampling was influenced not only by the skin metabolic status, but also by environmental conditions. The developed sampling setup (or "membrane sandwich") was used to compare two different modes of sampling: headspace and direct sampling. Results demonstrated that headspace sampling had significantly reduced background signal intensity, indicating minimized contamination from the skin surface. In addition, membrane storage conditions both before and after sampling were fully investigated. Membranes stored in dry ice for up to 72 h after collection were tested and showed no or minimal change in volatile profiles. This novel skin volatile compounds sampling approach coupled with gas chromatography-mass spectrometry (GC-MS) can achieve reproducible analysis. This technique was applied to identify the biomarkers of garlic intake and alcohol ingestion. Dimethyl sulphone, allyl methyl sulfide and allyl mercaptan, as metabolites of garlic intake, were detected. In addition, alcohol released from skin was also detected using our "membrane-sandwich" sampling. Using the same approach, we analyzed skin VOCs from upper back, forearm and back thigh regions of the body. Our results show that different body locations share a number of common compounds (27199). The area with most compounds detected was the upper back skin region, where the density of sebaceous glands is the highest. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 37 条
[1]  
Abaffy Tatjana, 2011, J Cancer Sci Ther, V3, P140
[2]   Differential Volatile Signatures from Skin, Naevi and Melanoma: A Novel Approach to Detect a Pathological Process [J].
Abaffy, Tatjana ;
Duncan, Robert ;
Riemer, Daniel D. ;
Tietje, Olaf ;
Elgart, George ;
Milikowski, Clara ;
DeFazio, R. Anthony .
PLOS ONE, 2010, 5 (11)
[3]  
[Anonymous], 2013, THESIS
[4]  
Bernier UR, 2007, J AM MOSQUITO CONTR, V23, P288, DOI 10.2987/8756-971X(2007)23[288:LCOAAA]2.0.CO
[5]  
2
[6]   Analysis of human skin emanations by gas chromatography mass spectrometry.: 1.: Thermal desorption of attractants for the yellow fever mosquito (Aedes aegypti) from handled glass beads [J].
Bernier, UR ;
Booth, MM ;
Yost, RA .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :1-7
[7]   Analysis of human skin emanations by gas chromatography/mass spectrometry.: 2.: Identification of volatile compounds that are candidate attractants for the yellow fever mosquito (Aedes aegypti) [J].
Bernier, UR ;
Kline, DL ;
Barnard, DR ;
Schreck, CE ;
Yost, RA .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :747-756
[8]   Sorptive tape extraction in the analysis of the volatile fraction emitted from biological solid matrices [J].
Bicchi, C. ;
Cordero, C. ;
Liberto, E. ;
Rubiolo, P. ;
Sgorbini, B. ;
Sandra, P. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1148 (02) :137-144
[9]   The frequency of occurrence and discriminatory power of compounds found in human scent across a population determined by SPME-GEMS [J].
Curran, Allison M. ;
Ramirez, Carlos F. ;
Schoon, Adee A. ;
Furton, Kenneth G. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2) :86-97
[10]   Comparison of the volatile organic compounds present in human odor using SPME-GC/MS [J].
Curran, AM ;
Rabin, SI ;
Prada, PA ;
Furton, KG .
JOURNAL OF CHEMICAL ECOLOGY, 2005, 31 (07) :1607-1619