Biodegradable implants in sports medicine:: The biological base

被引:155
作者
Weiler, A
Hoffmann, RFG
Stähelin, AC
Helling, HJ
Südkamp, NP
机构
[1] Humboldt Univ, Dept Trauma & Reconstruct Surg, Div Sports Traumatol & Arthroscopy, Virchow Clin, D-13353 Berlin, Germany
[2] Univ Cologne, Dept Trauma Hand & Reconstruct Surg, D-5000 Cologne 41, Germany
关键词
biodegradable implants; clinical application; sports medicine; biocompatibility; in vivo degradation;
D O I
10.1016/S0749-8063(00)90055-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Biodegradable implants are increasingly used in the field of operative sports medicine. Today, a tremendous variety of implants such as interference screws, staples, sutures, tacks, suture anchors, and devices for meniscal repair are available. These implants consist of different biodegradable polymers that have substantially different raw material characteristics such as in vivo degradation, host-tissue response, and osseous replacement. Because these devices have become the standard implant for several operative procedures, it is essential to understand their biological base. The purpose of this report is to provide a comprehensive insight into biodegradable implant biology for a better understanding of the advantages and risks associated with using these implants in the field of operative sports medicine. In particular, in vivo degradation, biocompatibility, and the osseous replacement of the implants are discussed. A standardized classification system to document and treat possible adverse tissue reactions is given, with special regard to extra-articular and intra-articular soft-tissue response and to osteolytic lesions.
引用
收藏
页码:305 / 321
页数:17
相关论文
共 122 条
[1]  
Agrawal CM, 1997, J BIOMED MATER RES, V38, P105, DOI 10.1002/(SICI)1097-4636(199722)38:2<105::AID-JBM4>3.0.CO
[2]  
2-U
[3]  
ANDERSON J, 1985, BIOMATERIALS, V2, P171
[4]  
ANDRIANO KP, 1994, J APPL BIOMATER, V11, P537
[5]   ARTHROSCOPIC BIOABSORBABLE TACK STABILIZATION OF INITIAL ANTERIOR SHOULDER DISLOCATIONS - A PRELIMINARY-REPORT [J].
ARCIERO, RA ;
TAYLOR, DC ;
SNYDER, RJ ;
UHORCHAK, JM .
ARTHROSCOPY, 1995, 11 (04) :410-417
[6]   Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid polyglycolic acid copolymers [J].
Athanasiou, KA ;
Niederauer, GG ;
Agrawal, CM .
BIOMATERIALS, 1996, 17 (02) :93-102
[7]   THE ULTIMATE STRENGTH OF SUTURE ANCHORS [J].
BARBER, FA ;
HERBERT, MA ;
CLICK, JN .
ARTHROSCOPY, 1995, 11 (01) :21-28
[8]   Suture anchor strength revisited [J].
Barber, FA ;
Herbert, MA ;
Click, JN .
ARTHROSCOPY, 1996, 12 (01) :32-38
[9]  
BARFOD G, 1992, ACTA ORTHOP SCAND, V63, P680
[10]  
BENNETT WF, 1998, 17 ANN M ARTHR ASS N