Prolonged Wireless pH Monitoring in Patients With Persistent Reflux Symptoms Despite Proton Pump Inhibitor Therapy

被引:30
作者
Hasak, Stephen [1 ]
Yadlapati, Rena [2 ]
Sweis, Rami [3 ]
Tucker, Emily [4 ,5 ]
Knowles, Kevin [4 ,5 ]
Fox, Mark [4 ,5 ,6 ]
Pandolfino, John [7 ]
Gyawali, C. Prakash [1 ]
Altayar, Osama [1 ]
机构
[1] Washington Univ, Sch Med, Div Gastroenterol, St Louis, MO 63110 USA
[2] Univ Calif San Diego, Div Gastroenterol, San Diego, CA 92103 USA
[3] Univ Coll London Hosp NHS Fdn Trust, GI Physiol Unit, London, England
[4] Nottingham Univ Hosp NHS Trust, NIHR Nottingham Biomed Res Ctr, Nottingham, England
[5] Univ Nottingham, Nottingham, England
[6] Klin Arlesheim, Ctr Integrat Gastroenterol, Lab & Clin Disorders Gastrointestinal Motil & Fun, Digest Funct Basel, Arlesheim, Switzerland
[7] Northwestern Univ, Div Gastroenterol, Feinberg Sch Med, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
GERD; Gastroesophageal Reflux Disease; Diagnostic; Prognostic; DIAGNOSIS; DISEASE; SENSITIVITY; MANAGEMENT; IMPACT; YIELD;
D O I
10.1016/j.cgh.2020.01.031
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: Wireless pH monitoring measures esophageal acid exposure time (AET) for up to 96 hours. We evaluated competing methods of analysis of wireless pH data. METHODS: Adult patients with persisting reflux symptoms despite acid suppression (n = 322, 48.5 - 0.9 years, 61.7% women) from 2 tertiary centers were evaluated using symptom questionnaires and wireless pH monitoring off therapy, from November 2013 through September 2017; 30 healthy adults (control subjects; 26.9 - 1.5 years; 60.0% women) were similarly evaluated. Concordance of daily AET (physiologic <4%, borderline 4%-6%, pathologic >6%) for 2 or more days constituted the predominant AET pattern. Each predominant pattern (physiologic, borderline, or pathologic) in relation to data from the first day, and total averaged AET, were compared with other interpretation paradigms (first 2 days, best day, or worst day) and with symptoms. RESULTS: At least 2 days of AET data were available from 96.9% of patients, 3 days from 90.7%, and 4 days from 72.7%. A higher proportion of patients had a predominant pathologic pattern (31.4%) than control subjects (11.1%; P = .03). When 3 or more days of data were available, 90.4% of patients had a predominant AET pattern; when 2 days of data were available, 64.1% had a predominant AET pattern (P < .001). Day 1 AET was discordant with the predominant pattern in 22.4% of patients and was less strongly associated with the predominant pattern compared with 48 hour AET (P = .059) or total averaged AET (P = .02). Baseline symptom burden was higher in patients with a predominant pathologic pattern compared with a predominant physiologic pattern (P = .02). CONCLUSIONS: The predominant AET pattern on prolonged wireless pH monitoring can identify patients at risk for reflux symptoms and provides gains over 24 hours and 48 hours recording, especially when results from the first 2 days are discordant or borderline.
引用
收藏
页码:2912 / 2919
页数:8
相关论文
共 23 条
[1]   Long-term wireless pH monitoring of the distal esophagus: prolonging the test beyond 48 hours is unnecessary and may be misleading [J].
Capovilla, G. ;
Salvador, R. ;
Spadotto, L. ;
Voltarel, G. ;
Pesenti, E. ;
Perazzolo, A. ;
Nicoletti, L. ;
Merigliano, S. ;
Costantini, M. .
DISEASES OF THE ESOPHAGUS, 2017, 30 (10) :1-8
[2]   Wireless 24, 48, and 96 Hour or Impedance or Oropharyngeal Prolonged pH Monitoring: Which Test, When, and Why for GERD? [J].
Chae S. ;
Richter J.E. .
Current Gastroenterology Reports, 2018, 20 (11)
[3]   Increasing yield also increases false positives and best serves to exclude GERD [J].
Connor, J ;
Richter, J .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (03) :460-463
[4]  
Fox MR, 2007, GASTROENTEROLOGY, V132, pA99
[5]   Modern diagnosis of GERD: the Lyon Consensus [J].
Gyawali, C. Prakash ;
Kahrilas, Peter J. ;
Savarino, Edoardo ;
Zerbib, Frank ;
Mion, Francois ;
Smout, Andre J. P. M. ;
Vaezi, Michael ;
Sifrim, Daniel ;
Fox, Mark R. ;
Vela, Marcelo F. ;
Tutuian, Radu ;
Tack, Jan ;
Bredenoord, Albert J. ;
Pandolfino, John ;
Roman, Sabine .
GUT, 2018, 67 (07) :1351-1362
[6]   Indications and interpretation of esophageal function testing [J].
Gyawali, C. Prakash ;
de Bortoli, Nicola ;
Clarke, John ;
Marinelli, Carla ;
Tolone, Salvatore ;
Roman, Sabine ;
Savarino, Edoardo .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 2018, 1434 (01) :239-253
[7]   Interference with daily activities and major adverse events during esophageal pH monitoring with bravo wireless capsule versus conventional intranasal catheter: a systematic review of randomized controlled trials [J].
Iluyomade, A. ;
Olowoyeye, A. ;
Fadahunsi, O. ;
Thomas, L. ;
Libend, C. N. ;
Ragunathan, K. ;
Fenster, J. ;
Vignesh, S. .
DISEASES OF THE ESOPHAGUS, 2017, 30 (03)
[8]   Development of the GerdQ, a tool for the diagnosis and management of gastro-oesophageal reflux disease in primary care [J].
Jones, R. ;
Junghard, O. ;
Dent, J. ;
Vakil, N. ;
Halling, K. ;
Wernersson, B. ;
Lind, T. .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2009, 30 (10) :1030-1038
[9]   Guidelines for the Diagnosis and Management of Gastroesophageal Reflux Disease [J].
Katz, Philip O. ;
Gerson, Lauren B. ;
Vela, Marcelo F. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2013, 108 (03) :308-328
[10]   Ambulatory esophageal pH monitoring using a wireless system [J].
Pandolfino, JE ;
Richter, JE ;
Ours, T ;
Guardino, JM ;
Chapman, J ;
Kahrilas, PJ .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (04) :740-749