Accelerometry-based method for assessing energy expenditure in patients with diabetes during walking

被引:4
|
作者
Caron, N. [1 ]
Peyrot, N. [2 ]
Caderby, T. [1 ]
Verkindt, C. [1 ]
Dalleau, G. [1 ]
机构
[1] Univ La Reunion, UFR Sci Homme & Environnement, Lab IRISSE, Le Tampon, France
[2] Univ Mans, UFR Sci & Techn, Lab MIP, Le Mans, France
关键词
accelerometer; diabetes mellitus; exercise; metabolic rate; PHYSICAL-ACTIVITY;
D O I
10.1111/jhn.12642
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background Monitoring activity-related energy expenditure (EE) is essential in the management of daily activity and the dietary programme in patients with type 2 diabetes (T2D) and must be estimated accurately. Accelerometry-based equations have frequently used to estimate EE, although the validity of these methods has not been confirmed in patients with T2D. The present study aimed to test the validity of an accelerometry-based method (Bouten's method) to assess EE during walking in patients with T2D. Methods The study included 20 patients with controlled T2D [mean (SD) duration: 10.6 (6.1) years; age: 57.5 (8.4) years; body mass index: 26.4 (2.6) kg m(-)(2)]. All participants performed five 6-min periods of walking at different speeds (0.5-1.5 m s(-1)) on a treadmill. Mechanical data were recorded using an inertial measurement unit placed on the lower back with gas exchange being simultaneously monitored. Results Values of EE during walking estimated by the accelerometer method did not differ significantly from those measured by indirect calorimetry. Bias and root mean square error were -1.17 and 2.93 kJ min(-1), respectively, on average across speeds. Conclusions Our results suggest that EE during walking may be accurately estimated in patients with diabetes mellitus using an accelerometer.
引用
收藏
页码:531 / 534
页数:4
相关论文
共 50 条
  • [21] Can energy expenditure be accurately assessed using accelerometry-based wearable motion detectors for physical activity monitoring in post-stroke patients in the subacute phase?
    Mandigout, Stephane
    Lacroix, Justine
    Ferry, Beatrice
    Vuillerme, Nicolas
    Compagnat, Maxence
    Daviet, Jean-Christophe
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2017, 24 (18) : 2009 - 2016
  • [22] Measurement accuracy of an accelerometry-based multi-sensor device for determining energy expenditure in normal weight, overweight and obese older persons
    Lange, M.
    Eckert, K.
    BEWEGUNGSTHERAPIE UND GESUNDHEITSSPORT, 2014, 30 (02): : 66 - 72
  • [23] Estimation of energy consumed by middle-aged recreational marathoners during a marathon using accelerometry-based devices
    Hernando, Carlos
    Hernando, Carla
    Martinez-Navarro, Ignacio
    Collado-Boira, Eladio
    Panizo, Nayara
    Hernando, Barbara
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [24] Estimation of energy consumed by middle-aged recreational marathoners during a marathon using accelerometry-based devices
    Carlos Hernando
    Carla Hernando
    Ignacio Martinez-Navarro
    Eladio Collado-Boira
    Nayara Panizo
    Barbara Hernando
    Scientific Reports, 10
  • [25] Using GPS, accelerometry and heart rate to predict outdoor graded walking energy expenditure
    de Mullenheim, P. -Y.
    Chaudru, S.
    Emily, M.
    Gernigon, M.
    Mahe, G.
    Bickert, S.
    Prioux, J.
    Noury-Desvaux, B.
    Le Faucheur, A.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2018, 21 (02) : 166 - 172
  • [26] Validity of estimating minute-by-minute energy expenditure of continuous walking bouts by accelerometry
    Erin E Kuffel
    Scott E Crouter
    Jere D Haas
    Edward A Frongillo
    David R Bassett
    International Journal of Behavioral Nutrition and Physical Activity, 8
  • [27] Validity of estimating minute-by-minute energy expenditure of continuous walking bouts by accelerometry
    Kuffel, Erin E.
    Crouter, Scott E.
    Haas, Jere D.
    Frongillo, Edward A.
    Bassett, David R., Jr.
    INTERNATIONAL JOURNAL OF BEHAVIORAL NUTRITION AND PHYSICAL ACTIVITY, 2011, 8
  • [29] Accelerometry-based physical activity and exercise capacity in pediatric kidney transplant patients
    Camillia G. Clark
    Marja Cantell
    Susan Crawford
    Lorraine A. Hamiwka
    Pediatric Nephrology, 2012, 27 : 659 - 665
  • [30] n Measurement Accuracy of an Accelerometry-based Multi-sensor Device for Determining Energy Expenditure in Normal Weight, Overweight and Obese Older Persons
    Lange, M.
    Eckert, K.
    AKTUELLE RHEUMATOLOGIE, 2014, 39 (05) : 322 - 328