Copper allergy from dental copper amalgam?

被引:4
作者
Gerhardsson, L [1 ]
Björkner, B
Karlsteen, M
Schütz, A
机构
[1] Univ Lund Hosp, Dept Occupat & Environm Med, SE-22185 Lund, Sweden
[2] Malmo Univ Hosp, Dept Occupat & Environm Dermatol, SE-20502 Malmo, Sweden
[3] Chalmers Univ Technol, Dept Phys, SE-41296 Gothenburg, Sweden
关键词
contact allergy; copper; saliva; tears; dental splint;
D O I
10.1016/S0048-9697(01)01055-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A 65-year-old female was investigated due to a gradually increasing greenish colour change of her plastic dental splint, which she used to prevent teeth grinding when sleeping. Furthermore, she had noted a greenish/bluish colour change on the back of her black gloves, which she used to wipe her tears away while walking outdoors. The investigation revealed that the patient had a contact allergy to copper, which is very rare. She had, however, had no occupational exposure to copper. The contact allergy may be caused by long-term exposure of the oral mucosa to copper from copper-rich amalgam fillings, which were frequently used in childhood dentistry up to the 1960s in Sweden. The deposition of a copper-containing coating on the dental splint may be caused by a raised copper intake from drinking water, increasing the copper excretion in saliva, in combination with release of copper due to electrochemical corrosion of dental amalgam. The greenish colour change of the surface of the splint is probably caused by deposition of a mixture of copper compounds, e.g. copper carbonates. Analysis by the X-ray diffraction technique indicates that the dominant component is copper oxide (Cu2O and CuO). The corresponding greenish/bluish discoloration observed on the back of the patient's gloves may be caused by increased copper excretion in tears. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 14 条
[1]  
Aaseth J., 1986, HDB TOXICOLOGY METAL, VII, P233
[2]  
AFSETH J, 1983, SCAND J DENT RES, V91, P42
[3]  
AHLGREN C, 2000, CONTACT DERMATITIS, V42, P10
[4]   STANDARD PATCH TEST SERIES FOR SCREENING OF CONTACT ALLERGY TO DENTAL MATERIALS [J].
AXELL, T ;
BJORKNER, B ;
FREGERT, S ;
NIKLASSON, B .
CONTACT DERMATITIS, 1983, 9 (01) :82-84
[5]  
*FOOD NUTR BOARD, 1980, COMM DIET ALL NAT RE
[6]  
Jenkins R., 1996, INTRO XRAY POWDER DI, DOI DOI 10.1016/S0341-8162(03)00040-7
[7]  
LAUBSTEIN B, 1990, Dermatologische Monatsschrift, V176, P421
[8]   CU2O AND CUCL2.3CU(OH)2 CORROSION PRODUCTS ON COPPER RICH DENTAL AMALGAMS [J].
MARSHALL, SJ ;
LIN, JHC ;
MARSHALL, GW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (01) :81-85
[9]  
Morris A, 1998, BRIT MED J, V316, P1902
[10]   RELEASE OF ELEMENTS DUE TO ELECTROCHEMICAL CORROSION OF DENTAL AMALGAM [J].
OLSSON, S ;
BERGLUND, A ;
BERGMAN, M .
JOURNAL OF DENTAL RESEARCH, 1994, 73 (01) :33-43