Characteristics of Probably Benign Breast MRI Lesions

被引:71
作者
Eby, Peter R. [1 ,2 ]
DeMartini, Wendy B. [1 ,2 ]
Gutierrez, Robert L. [1 ,2 ]
Saini, Monica H. [2 ]
Peacock, Sue [2 ]
Lehman, Constance D. [1 ,2 ]
机构
[1] Univ Washington, Med Ctr, Dept Radiol, Seattle, WA 98195 USA
[2] Seattle Canc Care Alliance, Seattle, WA 98109 USA
关键词
breast; breast neoplasms; MRI; probably benign; MAMMOGRAPHIC FOLLOW-UP; CANCER; BIOPSY; WOMEN;
D O I
10.2214/AJR.08.2096
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to describe the characteristics of probably benign breast MRI lesions and determine how these characteristics could be used to define the MRI BI-RADS 3 category. MATERIALS AND METHODS. We prospectively collected morphology and kinetic data on lesions assessed as BI-RADS 3 in 2.569 consecutive breast MRI examinations from January 2003 through November 2006. The clinical indications for MRI, follow-up assessments, and pathology findings through May 2008 were collected front clinical records. Data were linked to the regional tumor registry to identify cases of malignancy in patients who did not follow-up at our institution. Frequency of BI-RADS 3 and cancer yield were calculated. Characteristics of probably benign lesions were analyzed for predictors of malignancy. RESULTS. Three hundred sixty-two lesions were assessed as BI-RADS 3 in 260 (10.1%) of 2,569 examinations in 236 patients. The 362 lesions included 168 (46%) foci. 132 (36%) nonmasslike enhancements, and 62 (17%) masses. Delayed kinetic information was available in 275 lesions. The Most Suspicious delayed kinetic enhancement was persistent in 164 (60%) of 275, plateau in 47 (17%) of 275, and washout in 64 (23%) of 275. The cancer yield in patients with a BI-RADS 3 assessment was two (0.85%) of 236; both were ductal carcinoma in situ lesions. There were no malignancies in the 69 foci with 100% persistent enhancement. CONCLUSION. The characteristics of BI-RADS 3 lesions were highly variable in our population, and the risk of malignancy was low (0.85%). Assigning foci with 100% persistent enhancement to the BI-RADS 2 category call decrease the frequency of BI-RADS 3 assessment and maintain a likelihood of malignancy in less than 2% of cases.
引用
收藏
页码:861 / 867
页数:7
相关论文
共 22 条
[1]  
[Anonymous], 2003, BREAST IM REP DAT SY
[2]   ACCEPTABILITY OF PERIODIC FOLLOW-UP AS AN ALTERNATIVE TO BIOPSY FOR MAMMOGRAPHICALLY DETECTED LESIONS INTERPRETED AS PROBABLY BENIGN [J].
BRENNER, RJ ;
SICKLES, EA .
RADIOLOGY, 1989, 171 (03) :645-646
[3]  
BRENNER RJ, 1991, CURR OPIN RADIOL, V3, P588
[4]   Cancer yield of probably benign breast MR examinations [J].
Eby, Peter R. ;
DeMartini, Wendy B. ;
Peacock, Sue ;
Rosen, Eric L. ;
Lauro, Bridget ;
Lehman, Constance D. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) :950-955
[5]  
HALL FM, 1989, RADIOLOGY, V173, P284
[6]   MAMMOGRAPHIC FOLLOW-UP OF LOW-SUSPICION LESIONS - COMPLIANCE RATE AND DIAGNOSTIC YIELD [J].
HELVIE, MA ;
PENNES, DR ;
REBNER, M ;
ADLER, DD .
RADIOLOGY, 1991, 178 (01) :155-158
[7]  
Ikeda D M, 2001, Magn Reson Imaging Clin N Am, V9, P295
[8]   Development, standardization, and testing of a lexicon for reporting contrast-enhanced breast magnetic resonance imaging studies [J].
Ikeda, DM ;
Hylton, NM ;
Kinkel, K ;
Hochman, MG ;
Kuhl, CK ;
Kaiser, WA ;
Weinreb, JC ;
Smazal, SF ;
Degani, H ;
Viehweg, P ;
Barclay, J ;
Schnall, MD .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) :889-895
[9]  
Ikeda DM, 2000, J MAGN RESON IMAGING, V12, P975, DOI 10.1002/1522-2586(200012)12:6<975::AID-JMRI24>3.3.CO
[10]  
2-P