High-Speed Fluoroscopy to Measure Dynamic Spinal Cord Deformation in an In Vivo Rat Model

被引:7
|
作者
Lucas, Erin [1 ,2 ,3 ,4 ]
Whyte, Thomas [1 ,2 ,3 ,4 ]
Liu, Jie [4 ]
Russell, Colin [1 ,2 ,3 ,4 ]
Tetzlaff, Wolfram [4 ]
Cripton, Peter Alec [1 ,2 ,3 ,4 ]
机构
[1] Univ British Columbia, Dept Mech Engn, Orthopaed Injury Biomech Grp, Vancouver, BC, Canada
[2] Univ British Columbia, Dept Orthopaed, Orthopaed Injury Biomech Grp, Vancouver, BC, Canada
[3] Univ British Columbia, Sch Biomed Engn, Vancouver, BC, Canada
[4] Univ British Columbia, Int Collaborat Repair Discoveries ICORD, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
contusion; deformation; dynamic; in vivo; spinal cord; FINITE-ELEMENT MODEL; MECHANICAL-PROPERTIES; TISSUE-DAMAGE; INJURY; CONTUSION; DISLOCATION; STRAIN; MATTER; DISPLACEMENT; BIOMECHANICS;
D O I
10.1089/neu.2017.5478
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Although spinal cord deformation is thought to be a predictor of injury severity, few researchers have investigated dynamic cord deformation, in vivo, during impact. This is needed to establish correlations among impact parameters, internal cord deformation, and histological and functional outcomes. Relying on surface deformations alone may not sufficiently represent spinal cord deformation. The objective of this study was to develop a high-speed fluoroscopic method of tracking the surface and internal cord deformations of rat spinal cord during experimental cord injury. Two radio-opaque beads were injected into the cord at C5/6 in the dorsal and ventral white matter. Four additional beads were glued to the surface of the cord. Dynamic bead displacement was tracked during a dorsal impact (130mm/sec, 1mm depth) by high-speed radiographic imaging at 3000 FPS, laterally. The internal spinal cord beads displaced significantly more than the surface beads in the ventral direction (1.1-1.9 times) and more than most surface beads in the cranial direction (1.2-1.5 times). The dorsal beads (internal and surface) displaced more than the ventral beads during all impacts. The bead displacement pattern implies that the spinal cord undergoes complex internal and surface deformations during impact. Residual displacement of the internal beads was significantly greater than that of the surface beads in the cranial-caudal direction but not the dorsoventral direction. Finite element simulation confirmed that the additional bead mass likely had little effect on the internal cord deformations. These results support the merit of this technique for measuring in vivo spinal cord deformation.
引用
收藏
页码:2572 / 2580
页数:9
相关论文
共 50 条
  • [1] Radiography used to measure internal spinal cord deformation in an in vivo rat model
    Lucas, E.
    Whyte, T.
    Liu, J.
    Tetzlaff, W.
    Cripton, P. A.
    JOURNAL OF BIOMECHANICS, 2018, 71 : 286 - 290
  • [2] In Vivo Measurement of Cervical Spinal Cord Deformation During Traumatic Spinal Cord Injury in a Rodent Model
    Bhatnagar, Tim
    Liu, Jie
    Yung, Andrew
    Cripton, Peter A.
    Kozlowski, Piotr
    Oxland, Thomas
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (04) : 1285 - 1298
  • [3] Repeatability of a Dislocation Spinal Cord Injury Model in a Rat-A High-Speed Biomechanical Analysis
    Mattucci, Stephen
    Liu, Jie
    Fijal, Paul
    Tetzlaff, Wolfram
    Oxland, Thomas R.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (10):
  • [4] In vivo spinal cord deformation in flexion
    Yuan, Q
    Dougherty, L
    Margulies, SS
    PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1997, 1997, 3033 : 354 - 360
  • [5] Accuracy and feasibility of high-speed dual fluoroscopy and model-based tracking to measure in vivo ankle arthrokinematics
    Wang, Bibo
    Roach, Koren E.
    Kapron, Ashley L.
    Fiorentino, Niccolo M.
    Saltzman, Charles L.
    Singer, Madeline
    Anderson, Andrew E.
    GAIT & POSTURE, 2015, 41 (04) : 888 - 893
  • [6] Relating Histopathology and Mechanical Strain in Experimental Contusion Spinal Cord Injury in a Rat Model
    Bhatnagar, Tim
    Liu, Jie
    Yung, Andrew
    Cripton, Peter
    Kozlowski, Piotr
    Tetzlaff, Wolfram
    Oxland, Thomas
    JOURNAL OF NEUROTRAUMA, 2016, 33 (18) : 1685 - 1695
  • [7] In vivo human cervical spinal cord deformation and displacement in flexion
    Yuan, Q
    Dougherty, L
    Margulies, SS
    SPINE, 1998, 23 (15) : 1677 - 1683
  • [8] Dynamic changes in mechanical properties of the adult rat spinal cord after injury
    Jin, Chen
    Zhu, Rui
    Wang, Zhan-wei
    Li, Yi
    Ni, Hao-fei
    Xu, Meng-lei
    Zheng, Liang-dong
    Cao, Yu-ting
    Yang, Yi-ting
    Xu, Wei
    Wang, Jian-jie
    Xie, Ning
    Cheng, Li-ming
    ACTA BIOMATERIALIA, 2023, 155 : 436 - 448
  • [9] Biplanar High-Speed Fluoroscopy of Pony Superficial Digital Flexor Tendon (SDFT)-An In Vivo Pilot Study
    Wagner, Franziska C.
    Gerlach, Kerstin
    Geiger, Sandra M.
    Gittel, Claudia
    Bottcher, Peter
    Mulling, Christoph K. W.
    VETERINARY SCIENCES, 2021, 8 (06)
  • [10] In Vivo Measurement of Cervical Spinal Cord Deformation During Traumatic Spinal Cord Injury in a Rodent Model
    Tim Bhatnagar
    Jie Liu
    Andrew Yung
    Peter A. Cripton
    Piotr Kozlowski
    Thomas Oxland
    Annals of Biomedical Engineering, 2016, 44 : 1285 - 1298