Extracranial carotid Doppler ultrasound evaluation of cerebral blood flow volume in COPD patients

被引:23
作者
Albayrak, Ramazan [1 ]
Fidan, Fatma [1 ]
Unlu, Mehmet [1 ]
Sezer, Murat [1 ]
Degirmenci, Bumin [1 ]
Acar, Murat [1 ]
Haktanir, Alpay [1 ]
Yaman, Mehmet [1 ]
机构
[1] Afyon Kocatepe Univ, Fac Med, Dept Radiol, TR-03100 Afyon, Turkey
关键词
COPD; cerebral blood volume; Doppler ultrasound; carotid artery; vertebral artery;
D O I
10.1016/j.rmed.2006.01.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Doppler ultrasound of extracranial internal carotid artery (ICA) and vertebral artery (VA) were performed and total cerebral blood flow volume (tCBFV) was evaluated in chronic obstructive pulmonary disease (COPD) patients. CBFV changes due to blood gas changes were also evaluated. Methods: Bilateral ICA and VA have been examined with 7.5MHz Linear array transducer in COPD patients. Angle-corrected time averaged flow velocity and cross-sectional areas of vessels have been measured. Flow volumes and tCBFV have been calculated. Flow velocities and waveform parameters have been measured. Results: tCBFV, anterior-posterior CBFVs, left-right ICA flow volumes, bilateral ICA and VA cross-sectional areas and left ICA peak-systolic velocity were significantly higher in COPD patients than control group. Among COPD patients tCBFVs were highest in hypoxemic-hypercapnic ones, and lowest in normocapnic ones. Bilateral VA flow volumes, bilateral ICA (except left ICA V-ps) and VA flow velocities and waveform parameters were not different in COPD patients compared with control group. When compared among the subgroups of COPD patients, there were no significant differences for all parameters. Conclusion: tCBFVs were found to be significantly higher in COPD patients. This increment which is probably due to balancing the oxygen deficit is tow with hypoxemia and high with hypercapnia and hypoxemia. Particularly, bilateral ICA and VA cross-sectional area changes and increased left ICA V-ps were considered as the main reason for increased tCBFV in COPD patients. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1826 / 1833
页数:8
相关论文
共 50 条
  • [31] Hands Free Carotid Doppler Correlates with Cerebral Blood Flow in a Pediatric Porcine Model of Asphyxia Associated Cardiac Arrest
    Senthil, Kumaran
    Ko, Tiffany
    Gaudio, Hunter
    Jiang, Shunzhou
    Xiao, Rui
    Morgan, Ryan
    Skogvoll, Eirik
    Torp, Hans
    Kilbaugh, Todd
    Ingul, Charlotte
    CIRCULATION, 2024, 150 (25) : E751 - E752
  • [32] An assessment of the accuracy of renal blood flow estimation by Doppler ultrasound
    Wan, Li
    Yang, Natalie
    Hiew, Chee-Yan
    Schelleman, Anthony
    Johnson, Lynne
    May, Clive
    Bellomo, Rinaldo
    INTENSIVE CARE MEDICINE, 2008, 34 (08) : 1503 - 1510
  • [33] Doppler ultrasound tracking instrument for monitoring blood flow velocity
    von Krüger, MA
    Evans, DH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (11-12) : 1499 - 1508
  • [34] Envelope approximation on doppler ultrasound spectrogram for estimating flow speed in carotid artery
    Chien, Wei-Che
    Liu, Wei-Min
    Liu, An-Bang
    2016 INTERNATIONAL COMPUTER SYMPOSIUM (ICS), 2016, : 415 - 418
  • [35] A thin-walled carotid vessel phantom for doppler ultrasound flow studies
    Poepping, TL
    Nikolov, HN
    Thorne, ML
    Holdsworth, DW
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (08) : 1067 - 1078
  • [36] The relationship between cerebral blood flow and volume in humans
    Rostrup, E
    Knudsen, GM
    Law, I
    Holm, S
    Larsson, HBW
    Paulson, OB
    NEUROIMAGE, 2005, 24 (01) : 1 - 11
  • [37] An assessment of the accuracy of renal blood flow estimation by Doppler ultrasound
    Li Wan
    Natalie Yang
    Chee-Yan Hiew
    Anthony Schelleman
    Lynne Johnson
    Clive May
    Rinaldo Bellomo
    Intensive Care Medicine, 2008, 34 : 1503 - 1510
  • [38] Effects of carotid endarterectomy on cerebral blood flow and neuropsychological test performance in patients with high-grade carotid stenosis
    Kishikawa, K
    Kamouchi, M
    Okada, Y
    Inoue, T
    Ibayashi, S
    Iida, M
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2003, 213 (1-2) : 19 - 24
  • [39] Common Carotid Artery Occlusion Doppler Ultrasound Findings in Two Patients
    Monica, A. Nassauer
    Germano, A.
    Biscoito, L.
    Baptista, M.
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2005, 21 (06) : 502 - 508
  • [40] Comparison of Carotid Blood Flow Measured by Ultrasound and Cardiac Output in Patients Undergoing Cardiac Surgery
    Bu, Xin-yi
    Wang, Jian-kai
    Zhang, Yong
    Chen, Li-hai
    Liu, Jia-cong
    Zhao, Ya-mei
    Shi, Hong-wei
    Ge, Ya-li
    HEART SURGERY FORUM, 2023, 26 (03) : E234 - E239