Clinical Evaluation of Shaped Gel Breast Implant Rotation Using High-Resolution Ultrasound

被引:37
作者
Sieber, David A.
Stark, Ran Y. [1 ,2 ]
Chase, Serena [3 ]
Schafer, Mark [4 ]
Adams, William P., Jr. [1 ,2 ]
机构
[1] Univ Texas Southwestern, Dept Plast Surg, UTSW, Dallas, TX USA
[2] Univ Texas Southwestern, Aesthet Surg Fellowship, UTSW, Dallas, TX USA
[3] Xtant Med, Clin Affairs, Belgrade, MT USA
[4] PhotoSonix Med Inc, Signal Hill, CA USA
关键词
COHESIVE SILICONE GEL; AUGMENTATION; OUTCOMES; PROSTHESIS; SURGERY; TRIAL; CORE;
D O I
10.1093/asj/sjw179
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Clinical trials have demonstrated through core and independent studies that anatomical devices are safe and effective with low complication rates. The rotation rate of shaped breast implants in the literature is 0 to 8.2%. Currently there are no studies evaluating the efficacy of in office ultrasound or clinical rotation vs actual rotation rates seen on high-resolution ultrasound (HRUS). Objectives: The purpose of the study is to demonstrate the ease and reliability of HRUS for evaluating the rotation rate of 2 different brands of anatomic implants and to correlate this with the presumed clinical rate, as well as independent evaluators assessments. Methods: A total of 69 patients were followed up at routine intervals and were evaluated for rotation. Any implant rotated past > 30 degrees off of midline (outside 5-7 o'clock) was considered to be rotated. To determine if radiographic rotation was clinically evident, 20 composite patient photos were blindly evaluated. Results: A random total of 69 patients underwent bilateral augmentation mammoplasty with form stable anatimic gel implants using 138 implants. Twenty-nine of the 69 (42%) patients and 37 of the 138 (27%) implants were found to be rotated-using HRUS. Eight of the 69 (12%) patients had bilateral rotations. Independent evaluators were able to identify two of 12 (17%) possible rotations, or 2 rotations in 40 (5%) total implants. Conclusions: Anatomic form stable gel implants are actually rotated up to 25 times more frequently than previously thought, but these rotations do not translate into clinically significant sequela. High-resolution ultrasound is a simple alternative for breast implant surveillance and is better accepted by patients than magnetic resonance imaging (MRI). The clinical value of HRUS is also discussed and recommendations for FDA implant labeling changes are provided in this article.
引用
收藏
页码:290 / 296
页数:7
相关论文
共 27 条
[1]   The Process of Breast Augmentation: Four Sequential Steps for Optimizing Outcomes for Patients [J].
Adams, William P., Jr. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 122 (06) :1892-1900
[2]  
[Anonymous], 2011, PLASTIC SURG NEWS
[3]  
[Anonymous], 2011, FDA PAN DEB POST STU
[4]  
[Anonymous], 2013, SILICONE GEL FILLED
[5]   Transaxillary Totally Subfascial Breast Augmentation with Anatomical Breast Implants: Review of 27 Cases [J].
Aygit, Ahmet C. ;
Basaran, Karaca ;
Sen Mercan, Ebru .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (05) :1149-1156
[6]   High-Resolution Ultrasound in the Detection of Silicone Gel Breast Implant Shell Failure: Background, In Vitro Studies, and Early Clinical Results [J].
Bengtson, Bradley P. ;
Eaves, Felmont F. .
AESTHETIC SURGERY JOURNAL, 2012, 32 (02) :157-174
[7]  
Brown MH, 2005, PLAST RECONSTR SURG, V116, P768, DOI 10.1097/01.prs.0000176259.66948.e7
[8]   MemoryShape: Impact of Clinical Trials, Global Medical Economics, and the Future [J].
Cunningham, Bruce L. ;
Suszynski, Thomas ;
Sieber, David A. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 134 (03) :38S-45S
[9]   Textured Silicone Breast Implant Use in Primary Augmentation: Core Data Update and Review [J].
Derby, Brian M. ;
Codner, Mark A. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2015, 135 (01) :113-124
[10]  
Friedman Tal, 2006, Aesthet Surg J, V26, P530, DOI 10.1016/j.asj.2006.08.004