Autologous fibrin glue reinforced by platelets in surgery of ascending aorta

被引:13
作者
Christenson, JT [1 ]
Kalangos, A [1 ]
机构
[1] Univ Hosp, Cardiovasc Surg Clin, Dept Cardiovasc Surg, CH-1211 Geneva 24, Switzerland
关键词
surgery of ascending aorta; surgical glue; hemostasis; hemorrhage; costs;
D O I
10.1055/s-2004-821078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Fibrin sealants are popular for the improvement of perioperative hemostasis and reducing blood transfusion needs. Biological glues prepared from pooled human donor plasma have an inherent risk of transmission of blood-borne disease and are quite expensive to use. A system for the production of autologous Fibrin sealant reenforced by platelets has been developed. its efficacy, safety and economic benefits have been evaluated in a prospective, randomized study. Material: 20 consecutive patients undergoing replacement of the ascending aorta by the same surgical team had local application of either Tissucol(TM) (Group A) or autologous fibrin glue (Group B) for hemostasis. Results: No adverse effects of either glue were recorded. The volume of produced autologous fibrin glue was 25 cc PRR Platelet yield was 72%. The two groups were comparable. Efficacy was group comparable. Average cost for sealants in Group A was 470 +/- 100 Euros compared to 273 Euros in Group B, p = 0.004. Conclusions: Autologous fibrin glue reenforced by autologous platelets can be safely produced in the operating room in a large volume, with an comparable efficacy at a lower cost than commercial sealants.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 20 条
[1]  
BORST HG, 1982, J THORAC CARDIOV SUR, V84, P548
[2]   Systematic review of the use of fibrin sealant to minimize perioperative allogeneic blood transfusion [J].
Carless, PA ;
Anthony, DM ;
Henry, DA .
BRITISH JOURNAL OF SURGERY, 2002, 89 (06) :695-703
[3]  
Christenson J T, 1996, Eur J Cardiothorac Surg, V10, P1083, DOI 10.1016/S1010-7940(96)80355-1
[4]  
Fang WC, 1997, CIRCULATION, V96, P194
[5]   Fibrin sealants in surgical practice: An overview [J].
Jackson, MR .
AMERICAN JOURNAL OF SURGERY, 2001, 182 (02) :1S-7S
[6]   Frequency of transmission of human parvovirus B19 infection by fibrin sealant used during thoracic surgery [J].
Kawamura, M ;
Sawafuji, M ;
Watanabe, M ;
Horinouchi, H ;
Kobayashi, K .
ANNALS OF THORACIC SURGERY, 2002, 73 (04) :1098-1100
[7]   Controlled clinical studies of fibrin sealant in cardiothoracic surgery - A review [J].
Kjaergard, HK ;
Fairbrother, JE .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1996, 10 (09) :727-733
[8]   Vivostat system autologous fibrin sealant: Preliminary study in elective coronary bypass grafting [J].
Kjaergard, HK ;
Trumbull, HR .
ANNALS OF THORACIC SURGERY, 1998, 66 (02) :482-486
[9]   The use of autologous platelet-rich plasma (platelet gel) and autologous platelet-poor plasma (fibrin glue) in cosmetic surgery [J].
Man, D ;
Plosker, H ;
Winland-Brown, JE .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 107 (01) :229-237
[10]   The role of fibrin sealants in hemostasis [J].
Mankad, PS ;
Codispoti, M .
AMERICAN JOURNAL OF SURGERY, 2001, 182 (02) :21S-28S