Transcardiac conductance for continuous measurement of left ventricular volume: validation vs. angiography in patients

被引:3
作者
Staal, EM [1 ]
Baan, J [1 ]
Jukema, JW [1 ]
van der Wall, EE [1 ]
Steendijk, P [1 ]
机构
[1] Leiden Univ, Dept Cardiol, Med Ctr, NL-2300 RC Leiden, Netherlands
关键词
ventricular volume; monitoring; angiocardiography; ventricular remodeling;
D O I
10.1007/s00134-004-2300-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To test the feasibility of the transcardiac conductance (TCC) method for continuous, on-line measurement of absolute left ventricular (LV) volume and to validate the method by comparison with biplane angiography. Design and setting. Prospective clinical feasibility and validation study in a cardiac catheterization laboratory in a university hospital. Patients and interventions. Ten patients scheduled for electrophysiological studies (n=5), percutaneous transluminal coronary angioplasty (n=3), and left- and right-sided cardiac catheterization (n=2) were enrolled in the feasibility study. Twenty patients scheduled for diagnostic left- and right-sided cardiac catheterization were included in the validation study. The latter were studied at baseline and during right atrial pacing 30 beats/min above baseline. Measurements and results. In the feasibility study satisfactory ventricular volume signals were obtained by TCC in eight of ten patients. In the validation study calibration factors (alpha and V-p) for TCC were obtained by thermodilution and hypertonic saline dilution, to yield absolute LV volume. Results indicate a good linear correlation with angiographic volume (R-2=0.78) with an intercept of 10+/-15 ml, not significantly different from 0 and slope of 1.17+/-0.16. Mean calibration factors alpha and V-p were 0.017+/-0.002 (interpatient variability 0.018) and 75.1+/-0.4 ml (interpatient variability 35.4 ml), respectively. Conclusions. The TCC method provides on-line and continuous LV volume signals in patients in a relatively noninvasive way. Calibration yields absolute LV volumes with a good linear correlation in comparison to biplane LV angiography. TCC appears to be a promising methodology for monitoring absolute LV volume in the ICU.
引用
收藏
页码:1370 / 1376
页数:7
相关论文
共 18 条
  • [1] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [2] THE ORIGIN OF THE VARIATIONS OF BODY IMPEDANCE OCCURRING DURING THE CARDIAC CYCLE
    BONJER, FH
    VANDENBERG, J
    DIRKEN, MNJ
    [J]. CIRCULATION, 1952, 6 (03) : 415 - 420
  • [3] Prediction of 6 months left ventricular dilatation after myocardial infarction in relation to cardiac morbidity and mortality - Application of a new dilatation model to GISSI-3 data
    de Kam, PJ
    Nicolosi, GL
    Voors, AA
    van den Berg, MP
    Brouwer, J
    van Veldhuisen, DJ
    Barlera, S
    Maggioni, AP
    Giannuzzi, P
    Temporelli, PL
    Latini, R
    van Gilst, WH
    [J]. EUROPEAN HEART JOURNAL, 2002, 23 (07) : 536 - 542
  • [4] SEQUENCE OF MECHANICAL, ELECTROCARDIOGRAPHIC AND CLINICAL EFFECTS OF REPEATED CORONARY-ARTERY OCCLUSION IN HUMAN-BEINGS - ECHOCARDIOGRAPHIC OBSERVATIONS DURING CORONARY ANGIOPLASTY
    HAUSER, AM
    GANGADHARAN, V
    RAMOS, RG
    GORDON, S
    TIMMIS, GC
    DUDLETS, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 193 - 197
  • [5] Measuring critical heart data in the critical care setting
    Kass, DA
    [J]. CRITICAL CARE MEDICINE, 2000, 28 (05) : 1686 - 1687
  • [6] INFLUENCE OF CORONARY-OCCLUSION DURING PTCA ON END-SYSTOLIC AND END-DIASTOLIC PRESSURE-VOLUME RELATIONS IN HUMANS
    KASS, DA
    MIDEI, M
    BRINKER, J
    MAUGHAN, WL
    [J]. CIRCULATION, 1990, 81 (02) : 447 - 460
  • [7] Migrino RQ, 1997, CIRCULATION, V96, P116
  • [8] A meta-analysis of published studies concerning the validity of thoracic impedance cardiography
    Raaijmakers, E
    Faes, TJC
    Scholten, RJPM
    Goovaerts, HG
    Heethaar, RM
    [J]. ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 : 121 - 127
  • [9] Sabia P, 1991, CIRCULATION S1, V84, P185
  • [10] Comparison of continuous, stat, and intermittent cardiac output measurements in patients undergoing minimally invasive direct coronary artery bypass surgery
    Singh, A
    Juneja, R
    Mehta, Y
    Trehan, N