Effect of Implant Divergence on the Accuracy of Definitive Casts Created from Traditional and Digital Implant-Level Impressions: An In Vitro Comparative Study

被引:66
|
作者
Lin, Wei-Shao [1 ]
Harris, Bryan T. [1 ]
Elathamna, Eiad N. [1 ]
Abdel-Azim, Tamer [1 ]
Morton, Dean [1 ,2 ]
机构
[1] Univ Louisville, Sch Dent, Dept Oral Hlth & Rehabil, Louisville, KY 40292 USA
[2] Univ Louisville, Sch Dent, Adv Educ Prosthodont, Louisville, KY 40292 USA
关键词
dental implants; dental impression technique; digital impression; implant divergence; parallel confocal technology; RESTORATIONS; ANGULATION; PROSTHESES; FIT; TECHNOLOGY; FRAMEWORK; ABUTMENT;
D O I
10.11607/jomi.3592
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this research was to compare the accuracy of definitive casts created with digital and conventional methods for implants with internal-octagon connections placed parallel or at different angles (15, 30, or 45 degrees). Materials and Methods: Four customized epoxy resin master casts were fabricated with two-implant analogs placed in the posterior mandible with different degrees of divergence. For the conventional (control) group, 10 traditional impressions were taken on each master cast with custom trays, open-tray impression copings, and polyvinyl siloxane; definitive stone casts were poured with type IV dental stone. For the digital group, 10 digital impressions were taken on each master cast with two-piece scannable impression copings and an intraoral digital scanner; definitive milled polyurethane casts were fabricated by the manufacturer. All four master casts and 80 control and test casts were scanned and digitized, and the data sets were compared. Any deviations in measurements between the definitive and corresponding master casts were analyzed statistically. Results: The amount of divergence between implants did not affect the accuracy of the stone casts created conventionally; however, it significantly affected the accuracy of the milled casts created digitally. A decreasing linear trend in deviations for both distance and angle measurements suggested that the digital technique was more accurate when the implants diverged more. At 0 and 15 degrees of divergence, the digital method resulted in highly significantly less accurate definitive casts. At 30 and 45 degrees of divergence, however, the milled casts showed either no difference or marginal differences with casts created conventionally. Conclusion: The digital pathway produced less accurate definitive casts than the conventional pathway with the tested two-implant scenarios. To ensure passive fit of definitive prostheses, verification devices and casts may be used when materials are produced digitally.
引用
收藏
页码:102 / 109
页数:8
相关论文
共 50 条
  • [21] Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study
    Gedrimiene, Agne
    Adaskevicius, Rimas
    Rutkunas, Vygandas
    JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (05): : 271 - 279
  • [22] Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: A comparative in vitro study
    Hauschild, Uli
    Lerner, Henriette
    Weigl, Paul
    Porra, Tommaso
    Admakin, Oleg
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 150
  • [23] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    JOURNAL OF DENTISTRY, 2024, 146
  • [24] Conventional and Digital Impressions for Fabrication of Complete Implant-Supported Bars: A Comparative In Vitro Study
    Vieira, Samanta N. V.
    Lourenco, Matheus F.
    Pereira, Rodrigo C.
    Franca, Esdras C.
    Vilaca, Enio L.
    Silveira, Rodrigo R.
    Silva, Guilherme C.
    MATERIALS, 2023, 16 (11)
  • [25] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [26] Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches
    Rutkunas, Vygandas
    Cius, Darius Jegelevi
    Pletkus, Justinas
    Skalnis, Liudas Au
    Akulauskas, Mykolas
    Eyueboglu, Tan Firat
    Ozcan, Mutlu
    Gedrimiene, Agne
    JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (05): : 302 - 310
  • [27] Trueness of Extraoral Digital Impressions for Full-Arch Implant Impressions-In Vitro Study
    Sampaio-Fernandes, Manuel Antonio
    Pinto, Ricardo
    Almeida, Paulo Rocha
    Sampaio-Fernandes, Maria Margarida
    Marques, Duarte
    Figueiral, Maria Helena
    MATERIALS, 2024, 17 (12)
  • [28] Accuracy of intraoral photogrammetry versus direct digital implant impressions in the fully edentulous lower jaw: An in vitro study
    Brakoc, Jelena
    Todorovic, Ana
    Mangano, Francesco Guido
    Glisic, Mirko
    Scepanovic, Miodrag
    JOURNAL OF DENTISTRY, 2025, 156
  • [29] Accuracy of a novel stereophotogrammetry system for full-arch digital implant impressions: An in vitro study and clinical case
    Ye, Yuping
    Gu, Feifei
    Liang, Jixin
    Han, Juncheng
    Tang, Zhenzhong
    Song, Zhan
    MEASUREMENT, 2024, 244
  • [30] In vitro comparative study between complete arch conventional implant impressions and digital implant scans with scannable pick-up impression copings
    Conejo, Julian
    Yoo, Thomas H.
    Atria, Pablo J.
    Fraiman, Howard
    Blatz, Markus B.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 475e1 - 475e7