Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

被引:44
作者
Kim, Yun Ju [1 ]
Kim, Sung Hun [1 ]
Kang, Bong Joo [1 ]
Park, Chang Suk [3 ]
Kim, Hyeon Sook [4 ]
Son, Yo Han [5 ]
Porter, David Andrew [6 ]
Song, Byung Joo [2 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Radiol, Seoul 137701, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Gen Surg, Seoul 137701, South Korea
[3] Catholic Univ Korea, Incheon St Marys Hosp, Coll Med, Dept Radiol, Inchon 403720, South Korea
[4] Catholic Univ Korea, St Paul Hosp, Coll Med, Dept Radiol, Seoul 130709, South Korea
[5] Siemens Ltd, Healthcare Sect, Seoul 120837, South Korea
[6] Siemens AG, Healthcare Sect, D-91050 Erlangen, Germany
关键词
Breast neoplasm; Magnetic resonance imaging; Diffusion-weighted MRI; CLINICAL-APPLICATION; PEDIATRIC BRAIN; RESOLUTION;
D O I
10.3348/kjr.2014.15.4.403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Materials and Methods: Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between Lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. Results: The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the Lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Conclusion: Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast.
引用
收藏
页码:403 / 410
页数:8
相关论文
共 16 条
[1]   Magnetic resonance imaging of the breast prior to biopsy [J].
Bluemke, DA ;
Gatsonis, CA ;
Chen, MH ;
DeAngelis, GA ;
DeBruhl, N ;
Harms, S ;
Heywang-Köbrunner, SH ;
Hylton, N ;
Kuhl, CK ;
Lehman, C ;
Pisano, ED ;
Causer, P ;
Schnitt, SJ ;
Smazal, SF ;
Stelling, CB ;
Weatherall, PT ;
Schnall, MD .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (22) :2735-2742
[2]   Readout-segmented Echo-pIanar Imaging Improves the Diagnostic Performance of Diffusion-weighted MR Breast Examinations at 3.0 T [J].
Bogner, Wolfgang ;
Pinker-Domenig, Katja ;
Bickel, Hubert ;
Chmelik, Marek ;
Weber, Michael ;
Helbich, Thomas H. ;
Trattnig, Siegfried ;
Gruber, Stephan .
RADIOLOGY, 2012, 263 (01) :64-76
[3]   Diffusion-weighted MR for Differentiation of Breast Lesions at 3.0 T: How Does Selection of Diffusion Protocols Affect Diagnosis? [J].
Bogner, Wolfgang ;
Gruber, Stephan ;
Pinker, Katja ;
Grabner, Guenther ;
Stadlbauer, Andreas ;
Weber, Michael ;
Moser, Ewald ;
Helbich, Thomas H. ;
Trattnig, Siegfried .
RADIOLOGY, 2009, 253 (02) :341-351
[4]   Diffusion-weighted Imaging Improves the Diagnostic Accuracy of Conventional 3.0-T Breast MR Imaging [J].
El Khouli, Riham H. ;
Jacobs, Michael A. ;
Mezban, Sarah D. ;
Huang, Peng ;
Kamel, Ihab R. ;
Macura, Katarzyna J. ;
Bluemke, David A. .
RADIOLOGY, 2010, 256 (01) :64-73
[5]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[6]   Differentiation of clinically benign and malignant breast lesions using diffusion-weighted imaging [J].
Guo, Y ;
Cai, YQ ;
Cai, ZL ;
Gao, YG ;
An, NY ;
Ma, L ;
Mahankali, S ;
Gao, JH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :172-178
[7]   Clinical Application of Readout-Segmented-Echo-Planar Imaging for Diffusion-Weighted Imaging in Pediatric Brain [J].
Holdsworth, S. J. ;
Yeom, K. ;
Skare, S. ;
Gentles, A. J. ;
Barnes, P. D. ;
Bammer, R. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) :1274-1279
[8]   Detection of breast malignancy: Diagnostic MR protocol for improved specificity [J].
Huang, W ;
Fisher, PR ;
Dulaimy, K ;
Tudorica, LA ;
O'Hea, B ;
Button, TM .
RADIOLOGY, 2004, 232 (02) :585-591
[9]   The current status of breast MR imaging - Part I. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice [J].
Kuhl, Christiane .
RADIOLOGY, 2007, 244 (02) :356-378
[10]   Current status of breast MR imaging - Part 2. Clinical applications [J].
Kuhl, Christiane K. .
RADIOLOGY, 2007, 244 (03) :672-691