Treatment of Rabbit Elastase-Induced Aneurysm Models by Flow Diverters: Development of Quantifiable Indexes of Device Performance Using Digital Subtraction Angiography

被引:65
作者
Sadasivan, Chander [1 ]
Cesar, Liliana [3 ]
Seong, Jaehoon [4 ]
Wakhloo, Ajay K. [5 ,6 ]
Lieber, Baruch B. [1 ,2 ]
机构
[1] Univ Miami, Dept Biomed Engn, Coral Gables, FL 33146 USA
[2] Univ Miami, Dept Radiol, Coral Gables, FL 33146 USA
[3] Univ Miami, Endovasc Res Ctr, Vasc Biol Inst, Miami, FL 33136 USA
[4] Univ Cent Oklahoma, Dept Engn & Phys, Edmond, OK 73034 USA
[5] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[6] Univ Massachusetts, Sch Med, Dept Neurol Surg, Worcester, MA 01655 USA
基金
美国国家卫生研究院;
关键词
Convection; diffusion; intracranial aneurysm; lagged-normal distribution; mathematical modeling; pore density; porosity; stent; washout coefficient; INTRACRANIAL ANEURYSMS; CAROTID ANEURYSMS; STENT;
D O I
10.1109/TMI.2008.2012162
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
It has been known for more than a decade that intracranial aneurysms can be successfully treated by deploying a porous meshed tube in the parent vessel of the aneurysm. Such devices are currently called flow diverters because they promote intraneurysmal flow stasis and thrombosis by diverting blood flow away from the aneurysm sac. The objective of this study was to use angiographic data to quantify and compare the performance of flow diverters; of original design in successfully occluding an experimental aneurysm model. Three different configurations of a novel flow diverter with varying porosities and pore densities were implanted in 30 rabbit elastase-induced aneurysms. Temporal variations in angiographic contrast intensity within the aneurysms were fit to a mathematical model. Optimized model parameters were supplemented by the angiographic percentage aneurysm occlusion and an angiographic measure of device flexibility to derive composite scores of performance. Angiographic quantification further suggested a parameter, which could be employed to estimate long-term aneurysm occlusion probabilities immediately after treatment. Performance scores showed that the device with a porosity of 70% and pore density of 18 pores/mm(2) performed better than devices with 65% porosity, 14 pores/mm(2), and 70% porosity, 12 pores/mm(2) with relative efficacies of 100%, 84%, and 76%, respectively. The pore density of flow diverters, rather than porosity, may thus be a critical factor modulating device efficacy. A value of the prognostic parameter of less than 30 predicted greater than 97% angiographic aneurysm occlusion over six months with a sensitivity of 73% and specificity of 82%.
引用
收藏
页码:1117 / 1125
页数:9
相关论文
共 28 条
[1]   Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device [J].
Ahlhelm, Frank ;
Roth, Christian ;
Kaufmann, Ralf ;
Schulte-Altedorneburg, Gernot ;
Romeike, Bernd F. M. ;
Reith, Wolfgang .
NEURORADIOLOGY, 2007, 49 (12) :1023-1028
[2]   Creation of saccular aneurysms in the rabbit: A model suitable for testing endovascular devices [J].
Altes, TA ;
Cloft, HJ ;
Short, JG ;
DeGast, A ;
Do, HM ;
Helm, GA ;
Kallmes, DF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :349-354
[3]   Evaluation of intra-aneurysmal blood flow by digital subtraction angiography: Blood flow change after coil embolization [J].
Asakura, F ;
Tenjin, H ;
Sugawa, N ;
Kimura, S ;
Oki, F ;
Yonekawa, Y .
SURGICAL NEUROLOGY, 2003, 59 (04) :310-319
[4]   APPLICATIONS OF LAGGED NORMAL DENSITY CURVE AS A MODEL FOR ARTERIAL DILUTION CURVES [J].
BASSINGT.JB ;
ACKERMAN, FH ;
WOOD, EH .
CIRCULATION RESEARCH, 1966, 18 (04) :398-&
[5]   Analyzing attributes of vessel populations [J].
Bullitt, E ;
Muller, KE ;
Jung, IY ;
Lin, WL ;
Aylward, S .
MEDICAL IMAGE ANALYSIS, 2005, 9 (01) :39-49
[6]  
GEREMIA G, 1994, AM J NEURORADIOL, V15, P1223
[7]   Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events [J].
Gyöngyösi, M ;
Yang, P ;
Khorsand, A ;
Glogar, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) :1580-1589
[8]   Measurement and classification of retinal vascular tortuosity [J].
Hart, WE ;
Goldbaum, M ;
Côté, B ;
Kube, P ;
Nelson, MR .
INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 1999, 53 (2-3) :239-252
[9]   Asymmetric vascular stent feasibility study of a new low-porosity patch-containing stent [J].
Ionita, Ciprian N. ;
Paciorek, Ann M. ;
Hoffmann, Kenneth R. ;
Bednarek, Daniel R. ;
Yamamoto, Junichi ;
Kolega, John ;
Levy, Elad I. ;
Hopkins, L. Nelson ;
Rudin, Stephen ;
Mocco, J. .
STROKE, 2008, 39 (07) :2105-2113
[10]   A new endoluminal, flow-disrupting device for treatment of saccular aneurysms [J].
Kallmes, David F. ;
Ding, Yong Hong ;
Dai, Daying ;
Kadirvel, Ramanathan ;
Lewis, Debra A. ;
Cloft, Harry J. .
STROKE, 2007, 38 (08) :2346-2352