Stiffness Analysis and Control of a Stewart Platform-Based Manipulator With Decoupled Sensor-Actuator Locations for Ultrahigh Accuracy Positioning Under Large External Loads

被引:27
作者
Ding, Boyin [1 ]
Cazzolato, Benjamin S. [1 ]
Stanley, Richard M. [2 ,3 ]
Grainger, Steven [1 ]
Costi, John J. [2 ,3 ]
机构
[1] Univ Adelaide, Sch Mech Engn, Adelaide, SA 5005, Australia
[2] Flinders Univ S Australia, Biomech & Implants Res Grp, Med Device Res Inst, Bedford, SA 5042, Australia
[3] Flinders Univ S Australia, Sch Comp Sci Engn & Math, Bedford, SA 5042, Australia
来源
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME | 2014年 / 136卷 / 06期
关键词
compliance compensation; Stewart platform; decoupled sensor-actuator locations; control decoupling; PARALLEL; COMPENSATION; ROBOT;
D O I
10.1115/1.4027945
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Robot frame compliance has a large negative effect on the global accuracy of the system when large external forces/torques are exerted. This phenomenon is particularly problematic in applications where the robot is required to achieve ultrahigh (micron level) accuracy under very large external loads, e.g., in biomechanical testing and high precision machining. To ensure the positioning accuracy of the robot in these applications, the authors proposed a novel Stewart platform-based manipulator with decoupled sensor-actuator locations. The unique mechanism has the sensor locations fully decoupled from the actuator locations for the purpose of passively compensating for the load frame compliance, as a result improving the effective stiffness of the manipulator in six degrees of freedom (6DOF). In this paper, the stiffness of the proposed manipulator is quantified via a simplified method, which combines both an analytical model (robot kinematics error model) and a numerical model [finite element analysis (FEA) model] in the analysis. This method can be used to design systems with specific stiffness requirements. In the control aspect, the noncollocated positions of the sensors and actuators lead to a suboptimal control structure, which is addressed in the paper using a simple Jacobian-based decoupling method under both kinematics-and dynamics-based control. Simulation results demonstrate that the proposed manipulator configuration has an effective stiffness that is increased by a factor of greater than 15 compared to a general design. Experimental results show that the Jacobian-based decoupling method effectively increases the dynamic tracking performance of the manipulator by 25% on average over a conventional method.
引用
收藏
页数:12
相关论文
共 23 条
[1]   Frequency-dependent behavior of the intervertebral disc in response to each of six degree of freedom dynamic loading - Solid phase and fluid phase contributions [J].
Costi, John J. ;
Stokes, Ian A. ;
Gardner-Morse, Mack G. ;
Iatridis, James C. .
SPINE, 2008, 33 (16) :1731-1738
[2]  
Coulombe J, 2013, IEEE INT CONF ROBOT, P877, DOI 10.1109/ICRA.2013.6630676
[3]   A Newton-Euler formulation for the inverse dynamics of the stewart platform manipulator [J].
Dasgupta, B ;
Mruthyunjaya, TS .
MECHANISM AND MACHINE THEORY, 1998, 33 (08) :1135-1152
[4]   The Stewart platform manipulator: a review [J].
Dasgupta, B ;
Mruthyunjaya, TS .
MECHANISM AND MACHINE THEORY, 2000, 35 (01) :15-40
[5]  
Ding B., 2011, P 37 C IEEE IND EL S, P211
[6]  
Do W. Q. D., 1998, J ROBOTIC SYST, V5, P209
[7]  
EI-Khasawneh B. S., 1999, INT J MACH TOOL MANU, V39, P321
[8]   Optimised robot-based system for the exploration of elastic joint properties [J].
Frey, M ;
Burgkart, R ;
Regenfelder, F ;
Riener, R .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (05) :674-678
[9]  
Fujie H, 1996, J BIOMECH, V29, P1577, DOI 10.1016/0021-9290(96)00075-9
[10]   THE USE OF ROBOTICS TECHNOLOGY TO STUDY HUMAN JOINT KINEMATICS - A NEW METHODOLOGY [J].
FUJIE, H ;
MABUCHI, K ;
WOO, SLY ;
LIVESAY, GA ;
ARAI, S ;
TSUKAMOTO, Y .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (03) :211-217