Study on Shielding Failure Flashover Rate for EHV Transmission Line

被引:0
|
作者
Fan Chun-lei [1 ]
Wu Guang-ning [1 ]
Li Rui-fang [1 ]
机构
[1] SW Jiaotong Univ, Sch Elect Engn, Chengdu, Peoples R China
关键词
transmission line; shielding failure flashover rate; striking distance factor; uncovered distance;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Lightning is the main reason that endangers the safety and reliability of transmission line, but the existing models of estimating shielding failure flashover rate can not be in agreement with field experience at present. This paper deals with shielding failure flashover rate of the EHV transmission lines with many parameters by the improved electric-geometry model. The parameters consist of phase wires, shield wires, and the ground angle. In the improved model, "strike distance" is calculated with the expression recommended by IEEE, "the striking distance factor" is introduced to describe the difference of electric intensity between lightning stroke on the transmission tine and the ground, and the "uncovered distance" is adopted to calculate shielding failure flashover rate for ultra high voltage transmission line. Taking 500kV transmission line as example, the improved electric-geometry model gets the result in agreement with field experience. Compared with the order of the method, it is more accurately. At the same time, the paper analyzes the influence of the shielding angle, the height of wire, the grounding obliquity on shielding failure flashover rate. The results of studies show that the shielding failure flashover rate is a function of the shielding angle, ground angle and the height of tower. It will increase with the increase of the grounding obliquity, protection angle and the height of tower. The simulation calculation shows that when the shielding angle is -6.24 degrees, the shielding failure flashover rate reduces from 0.2135 to 0 in this paper. It will help designers in making the correct economic judgment.
引用
收藏
页码:172 / 175
页数:4
相关论文
共 50 条
  • [1] Bird Streamer Caused Flashover in EHV Transmission Line
    Zhou, Y. X.
    Xu, X.
    Nie, Q.
    Liang, X. D.
    Guan, Z. C.
    Cui, J. F.
    Li, Z. Y.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) : 69 - 76
  • [2] Icing flashover characteristics of EHV AC transmission line insulator strings
    Huang, Dao-Chun
    Liu, Yun-Peng
    Hu, Yi
    Cai, Wei
    Chen, Yong
    Ruan, Jiang-Jun
    Yu, Tao
    Yao, Tao
    Xu, Zuo-Ming
    Gao, Song
    Lu, Jie
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (03): : 568 - 573
  • [3] GRNN applied to study the lightning shielding performance for EHV&UHV transmission line
    Deng Wei
    Lan Lei
    Peng Xudong
    Fu Zhiyang
    Liu Weidong
    Wen Xishan
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 660 - +
  • [4] Three-dimensional method of calculating shielding failure flashover times of transmission line in complex terrain area
    Sima, Wenxia
    Zheng, Haoyuan
    Yang, Qing
    Yuan, Tao
    Jiang, Wendong
    Cao, Jiong
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (03): : 662 - 668
  • [5] Analysis of Arrester Energy for 132kV Overhead Transmission Line due to Back Flashover and Shielding Failure
    Abu Bakar, Ab Halim
    Mokhlis, Hazlie
    Abd Halim, Syahirah
    Isa, Siti Sarah Mat
    Illias, Hazlee Azil
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [6] Analysis of Arrester Energy for 132kV Overhead Transmission Line due to Back Flashover and Shielding Failure
    Hassan, Nor Hidayah Nor
    Abu Bakar, Ab Halim
    Mokhlis, Hazlie
    Illias, Hazlee Azil
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 683 - 688
  • [7] Influence of transmission line tower grounding impedance to the line flashover rate
    Stojkovic, Z
    Savic, MS
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1999, 9 (04): : 261 - 270
  • [8] Study on Tower Models for EHV Transmission Line
    Xu, Bao-Qing
    Zhang, Xiao-Fei
    Lv, Sen
    Ding, Rui-Xin
    Wang, Lu
    2016 8TH INTERNATIONAL CONFERENCE ON COMPUTER AND AUTOMATION ENGINEERING (ICCAE 2016), 2016, 56
  • [10] Icing flashover process and its influential factors of long insulator strings on the ehv transmission line
    Department of Electrical Engineering, North China Electric Power University, Baoding 071003, China
    不详
    不详
    Gaodianya Jishu, 2009, 3 (557-562):