High-accuracy displacement metrology and control using a dual Fabry-Perot cavity with an optical frequency comb generator

被引:21
作者
Bitou, Youichi [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058563, Japan
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2009年 / 33卷 / 02期
关键词
Displacement; Optical frequency comb; Fabry-Perot cavity; Sub-nm; Uncertainty; TUNABLE DIODE-LASER; INTERFEROMETER; CALIBRATION; NONLINEARITY; RESOLUTION; SCALES; AIR;
D O I
10.1016/j.precisioneng.2008.05.004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A displacement metrology and control system using an optical frequency comb generator and a dual Fabry-Perot cavity is developed with sub-nm accuracy. The optical frequency comb generator has expanded the displacement measurement range and the dual cavity system has suppressed the environmental fluctuation. We evaluated the absolute uncertainty of the developed displacement measurement system to be approximately 190 pm for the displacement of 14 mu m and the accurate displacement control using a phase-locked loop was demonstrated with a resolution of approximately 24 pm. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 20 条
[1]   Accurate wide-range displacement measurement using tunable diode laser and optical frequency comb generator [J].
Bitou, Y ;
Schibli, TR ;
Minoshima, K .
OPTICS EXPRESS, 2006, 14 (02) :644-654
[2]   Rubidium-stabilized diode laser for high-precision interferometer [J].
Bitou, Y ;
Sasaki, K ;
Inaba, H ;
Hong, FL ;
Onae, A .
OPTICAL ENGINEERING, 2004, 43 (04) :900-903
[3]   A laser measurement system for the high-precision calibration of displacement transducers [J].
Brand, U ;
Herrmann, K .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (06) :911-917
[4]   Nanometer measurement with a dual Fabry-Perot interferometer [J].
Chen, BY ;
Zhu, RG ;
Wu, ZT ;
Li, DC ;
Guo, SL .
APPLIED OPTICS, 2001, 40 (31) :5632-5637
[5]   Refractive index of air: New equations for the visible and near infrared [J].
Ciddor, PE .
APPLIED OPTICS, 1996, 35 (09) :1566-1573
[6]   A simple method for the compensation of the nonlinearity in the heterodyne interferometer [J].
Eom, T ;
Choi, T ;
Lee, K ;
Choi, H ;
Lee, S .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (02) :222-225
[7]   Calibration of displacement sensors up to 300 μm with nanometre accuracy and direct traceability to a primary standard of length [J].
Haitjema, H ;
Schellekens, PHJ ;
Wetzels, SFCL .
METROLOGIA, 2000, 37 (01) :25-33
[8]   Real-time displacement measurements with a Fabry-Perot cavity and a diode laser [J].
Howard, L ;
Stone, J ;
Fu, J .
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2001, 25 (04) :321-335
[9]   Removing nonlinearity of a homodyne interferometer by adjusting the gains of its quadrature detector systems [J].
Keem, T ;
Gonda, S ;
Misumi, I ;
Huang, QX ;
Kurosawa, T .
APPLIED OPTICS, 2004, 43 (12) :2443-2448
[10]   WIDE-SPAN OPTICAL FREQUENCY COMB GENERATOR FOR ACCURATE OPTICAL FREQUENCY DIFFERENCE MEASUREMENT [J].
KOUROGI, M ;
NAKAGAWA, K ;
OHTSU, M .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1993, 29 (10) :2693-2701