Fouling of an anion exchange membrane in the electrodialysis desalination process in the presence of organic foulants

被引:133
作者
Lee, Hong-Joo [1 ]
Hong, Min-Kyoung [1 ]
Han, Sang-Don [1 ]
Cho, Seung-Hee [1 ]
Moon, Seung-Hyeon [1 ]
机构
[1] GIST, Dept Environm Sci & Engn, Kwangju 500712, South Korea
关键词
Electrodialysis; Fouling; Organic foulant; Anion exchange membrane; Adsorption capacity; AQUEOUS-SOLUTION; ION-EXCHANGE; SEA-WATER; ADSORPTION;
D O I
10.1016/j.desal.2008.01.036
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Interest in desalination using membrane processes has increased with the growth of membrane science and technology. Fouling of ion exchange membranes is one of the most significant considerations in the operation of the electrodialysis desalination process. The influence of the adsorption capacity of foulants on the fouling potential was investigated in an electrodialysis desalination process in the presence of negatively charged organic foulants, humate, bovine serum albumin and sodium dodecylbenzenesulfonate (SDBS). The SDBS showed higher adsorption capacity on the anion exchange membrane surface than the other two foulants in the adsorption equilibrium experiments. Of three different organic foulants, the SDBS had a more severe fouling effect on the process performance in the electrodialysis desalination of synthetic brackish water, with irreversible fouling due to the high adsorption capacity. The study clearly showed that the adsorption capacity affects the fouling potential of the electrodialysis desalination process.
引用
收藏
页码:60 / 69
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 2004, ION EXCHANGE MEMBRAN
[2]  
Belfort G., 1984, SYNTHETIC MEMBRANE P
[3]   Kinetic modelling of the adsorption of nitrates by ion exchange resin [J].
Chabani, M. ;
Amrane, A. ;
Bensmaili, A. .
CHEMICAL ENGINEERING JOURNAL, 2006, 125 (02) :111-117
[4]   Kinetics and adsorption behavior of carboxymethyl starch on α-alumina in aqueous medium [J].
Chen, Yanxiao ;
Liu, Shaoying ;
Wang, Gongying .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2006, 303 (02) :380-387
[5]   Removal of Cr(VI) from aqueous solution by two Lewatit-anion exchange resins [J].
Gode, F ;
Pehlivan, E .
JOURNAL OF HAZARDOUS MATERIALS, 2005, 119 (1-3) :175-182
[6]  
GWI, 2004, DES MARK 2005 2015
[7]   ENGINEERING DESIGN OF A 6000 M3-DAY SEA-WATER HYBRID RO-ED HELIO-DESALTING PLANT [J].
HUSSEINY, AA ;
HAMESTER, HL .
DESALINATION, 1981, 39 (1-3) :171-172
[8]   MECHANISMS FOR BSA FOULING DURING MICROFILTRATION [J].
KELLY, ST ;
ZYDNEY, AL .
JOURNAL OF MEMBRANE SCIENCE, 1995, 107 (1-2) :115-127
[9]   FOULING OF ANIONSELECTIVE MEMBRANES IN ELECTRODIALYSIS [J].
KORNGOLD, E ;
DEKOROSY, F ;
RAHAV, R ;
TABOCH, MF .
DESALINATION, 1970, 8 (02) :195-&
[10]   Characterization of anion exchange membranes fouled with humate during electrodialysis [J].
Lee, HJ ;
Choi, JH ;
Cho, JW ;
Moon, SH .