Lipidomic analysis of polyunsaturated fatty acids and their oxygenated metabolites in plasma by solid-phase extraction followed by LC-MS

被引:32
作者
Dasilva, Gabriel [1 ]
Pazos, Manuel [1 ]
Gallardo, Jose M. [1 ]
Rodriguez, Isaac [2 ]
Cela, Rafael [2 ]
Medina, Isabel [1 ]
机构
[1] Consejo Super Invest Cient IIM CSIC, Inst Invest Marinas, Vigo 36208, Galicia, Spain
[2] Univ Santiago de Compostela, Res Inst Food Anal IIAA, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Galicia, Spain
关键词
Oxygenated lipidmediators; Solid-phase extraction; Liquid chromatography; Mass spectrometry; Triple quadrupole; Ion trap; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; IN-VIVO; ANTIINFLAMMATORY PROPERTIES; F-2-ISOPROSTANE ANALYSIS; EICOSAPENTAENOIC ACID; OXIDATION-PRODUCTS; ARACHIDONIC-ACID; HUMAN URINE; EICOSANOIDS;
D O I
10.1007/s00216-014-7701-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present work describes the development of a robust and sensitive targeted analysis platform for the simultaneous quantification in blood plasma of lipid oxygenated mediators and fatty acids using solid-phase extraction (SPE) and high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). The concurrent analysis of these lipid mediators is challenging because of their instability, differences in solubility, and the frequent occurrence of isobaric forms with similar fragmentation patterns. Results demonstrated that the reduction of SPE temperature to 4 A degrees C is a critical parameter for preserving the hydroperoxy derivatives. Polymeric HLB cartridges increased 40-50 % ARA, EPA, and DHA sensitivity compared to C18 sorbent and also provided higher global performance for most hydroxides and other oxidation products. The proposed method for the two tested mass analyzers yields high sensitivity, good linearity, and reproducibility, with detection limits ranging 0.002-7 ng/mL and global recoveries as high as 85-112 %. However, the additional advantage of the linear ion trap (LIT) mass analyzer working in full scan product ion mode, compared to the triple quadrupole (QqQ) operating in multiple reaction monitoring (MRM), should be noted: the full scan product ion mode provides the full fragmentation spectra of compounds that allowed the discrimination of coeluting isomers and false positive identifications without additional chromatography development. The proposed lipidomic procedure demonstrates a confident, simple, and sensitive method to profile in plasma a wide range of lipid eicosanoid and docosanoid mediators, including innovatively the analysis of hydroperoxy congeners and nonoxidized PUFA precursors.
引用
收藏
页码:2827 / 2839
页数:13
相关论文
共 43 条
[1]   Stereochemical assignment, antiinflammatory properties, and receptor for the omega-3 lipid mediator resolvin E1 [J].
Arita, M ;
Bianchini, F ;
Aliberti, J ;
Sher, A ;
Chiang, N ;
Hong, S ;
Yang, R ;
Petasis, NA ;
Serhan, CN .
JOURNAL OF EXPERIMENTAL MEDICINE, 2005, 201 (05) :713-722
[2]   Simultaneous quantification of 8-iso-prostaglandin-F2α and 11-dehydro thromboxane B2 in human urine by liquid chromatography-tandem mass spectrometry [J].
Cavalca, Viviana ;
Minardi, Fabiana ;
Scurati, Samuele ;
Guidugli, Federico ;
Squellerio, Isabella ;
Veglia, Fabrizio ;
Dainese, Luca ;
Guarino, Anna ;
Tremoli, Elena ;
Caruso, Donatella .
ANALYTICAL BIOCHEMISTRY, 2010, 397 (02) :168-174
[3]   In vivo formation of 8-epi-prostaglandin F-2 alpha is increased in hypercholesterolemia [J].
Davi, G ;
Alessandrini, P ;
Mezzetti, A ;
Minotti, G ;
Bucciarelli, T ;
Costantini, F ;
Cipollone, F ;
Bon, GB ;
Ciabattoni, G ;
Patrono, C .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (11) :3230-3235
[4]   Detection and quantitation of eicosanoids via high performance liquid chromatography-electrospray ionization-mass spectrometry [J].
Deems, Raymond ;
Buczynski, Matthew W. ;
Bowers-Gentry, Rebecca ;
Harkewicz, Richard ;
Dennis, Edward A. .
LIPIDOMICS AND BIOACTIVE LIPIDS: MASS-SPECTROMETRY-BASED LIPID ANALYSIS, 2007, 432 :59-82
[5]   8-Epi PGF(2 alpha) generation during coronary reperfusion - A potential quantitative marker of oxidant stress in vivo [J].
Delanty, N ;
Reilly, MP ;
Pratico, D ;
Lawson, JA ;
McCarthy, JF ;
Wood, AE ;
Ohnishi, ST ;
Fitzgerald, DJ ;
FitzGerald, GA .
CIRCULATION, 1997, 95 (11) :2492-2499
[6]   Mass spectrometric analysis of leukotriene A4 and other chemically reactive metabolites of arachidonic acid [J].
Dickinson, JS ;
Murphy, RC .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (10) :1227-1234
[7]   Lipidomic analysis reveals prostanoid profiles in human term pregnant myometrium [J].
Durn, J. H. ;
Marshall, K. M. ;
Farrar, D. ;
O'Donovan, P. ;
Scally, A. J. ;
Woodward, D. F. ;
Nicolaou, A. .
PROSTAGLANDINS LEUKOTRIENES AND ESSENTIAL FATTY ACIDS, 2010, 82 (01) :21-26
[8]   Automated targeting analysis of eicosanoid inflammation biomarkers in human serum and in the exometabolome of stem cells by SPE-LC-MS/MS [J].
Ferreiro-Vera, Carlos ;
Maria Mata-Granados, Jose ;
Priego-Capote, Feliciano ;
Manuel Quesada-Gomez, Jose ;
Dolores Luque de Castro, Maria .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (03) :1093-1103
[9]  
Frankel E.N., 1998, Lipid oxidation
[10]   Formation of F-ring isoprostane-like compounds (F3-isoprostanes) in vivo from eicosapentaenoic acid [J].
Gao, Ling ;
Yin, Huiyong ;
Milne, Ginger L. ;
Porter, Ned A. ;
Morrow, Jason D. .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2006, 281 (20) :14092-14099