A simple and flexible enzymatic glucose biosensor using chitosan entrapped mesoporous carbon nanocomposite

被引:49
作者
Barathi, Palani [1 ,2 ]
Thirumalraj, Balamurugan [3 ,4 ]
Chen, Shen-Ming [4 ]
Angaiah, Subramania [2 ]
机构
[1] Indian Inst Sci, Dept Inorgan & Phys Chem, Bangalore 560012, Karnataka, India
[2] Pondicherry Univ, Ctr Nanosci & Technol, Electrochem Energy Res Lab, Pondicherry 605014, India
[3] Natl Taiwan Univ Sci & Technol, Dept Chem Engn, Taipei 10607, Taiwan
[4] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, 1 Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
关键词
Mesoporous carbon; Chitosan; Glucose oxidase; Direct electrochemistry; Glucose biosensor; DIRECT ELECTRON-TRANSFER; REDUCED GRAPHENE OXIDE; LAYER-BY-LAYER; DIRECT ELECTROCHEMISTRY; POROUS CARBON; QUANTUM DOTS; NANOTUBES; NANOPARTICLES; IMMOBILIZATION; COMPOSITE;
D O I
10.1016/j.microc.2019.03.083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flexible and promising amperometric glucose biosensor was reported using direct immobilization of glucose oxidase (GOx) on chitosan supported mesoporous carbon (MPC-CHT) nanocomposite. The availability of more functional groups particularly amine groups, the CHT was selected as an immobilization matrix as well as cross linker for GOx. The MPC-CHT-GOx composites were characterized well and discussed in details. The MPC-CHT-GOx modified electrode accelerates fast electron transfer on the electrode surface due to the excellent intermolecular interaction between the CHT and GOx molecule. Besides, the MPC-CHT-GOx composite showed well-defined redox behavior with enhanced direct electron transfer (DET) of GOx in PBS, pH 7. Amperometric response of MPC-CHT-GOx modified electrode displayed a good linear response over the glucose concentration ranges from 250 mu M to 3 mM with a detection limit (LOD) and sensitivity of 4.1 mu M and 56.12 mu A mM(-1) cm(-2), respectively. The MPC-CHT-GOx modified electrode also displayed good charge transfer coefficient (alpha) and heterogeneous rate constant (k(s)) values are 0.56 and 2.2182 s(-1). Besides, the MPC-CHT-GOx modified electrode exhibited good bio-catalytic activity with the Michaelis-Menten saturation (K-m(app)) value was about 2.14 mM. The practicability of the sensor was evaluated in biological real samples with satisfactory recoveries.
引用
收藏
页码:848 / 856
页数:9
相关论文
共 50 条
[1]   Glucose oxidase - An overview [J].
Bankar, Sandip B. ;
Bule, Mahesh V. ;
Singhal, Rekha S. ;
Ananthanarayan, Laxmi .
BIOTECHNOLOGY ADVANCES, 2009, 27 (04) :489-501
[2]   A glucose biosensor based on glucose oxidase immobilized on three-dimensional porous carbon electrodes [J].
Chen, Jingyi ;
Zhu, Rong ;
Huang, Jia ;
Zhang, Man ;
Liu, Hongyu ;
Sun, Min ;
Wang, Li ;
Song, Yonghai .
ANALYST, 2015, 140 (16) :5578-5584
[3]   Recent advances on developing 3rd generation enzyme electrode for biosensor applications [J].
Das, Priyanki ;
Das, Madhuri ;
Chinnadayyala, Somasekhar R. ;
Singha, Irom Manoj ;
Goswami, Pranab .
BIOSENSORS & BIOELECTRONICS, 2016, 79 :386-397
[4]   Acidic and Basic Functionalized Carbon Nanomaterials as Electrical Bridges in Enzyme Loaded Chitosan/Poly(styrene sulfonate) Self-Assembled Layer-by-Layer Glucose Biosensors [J].
David, Melinda ;
Barsan, Madalina M. ;
Florescu, Monica ;
Brett, Christopher M. A. .
ELECTROANALYSIS, 2015, 27 (09) :2139-2149
[5]   A sensitive and stable biosensor based on the direct electrochemistry of glucose oxidase assembled layer-by-layer at the multiwall carbon nanotube-modified electrode [J].
Deng, Chunyan ;
Chen, Jinhua ;
Nie, Zhou ;
Si, Shihui .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :213-219
[6]   Molecular "Wiring" glucose oxidase in supramolecular architecture [J].
Deng, Liu ;
Liu, Ying ;
Yang, Guocheng ;
Shang, Li ;
Wen, Dan ;
Wang, Fuan ;
Xu, Zhiai ;
Dong, Shaojun .
BIOMACROMOLECULES, 2007, 8 (07) :2063-2071
[7]   Direct electrochemistry of glucose oxidase on a graphite nanosheet-Nafion composite film modified electrode [J].
Fu, Chenglin ;
Yang, Wensheng ;
Chen, Xu ;
Evans, David G. .
ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (05) :997-1000
[8]   Engineering of Glucose Oxidase for Direct Electron Transfer via Site-Specific Gold Nanoparticle Conjugation [J].
Holland, J. Todd ;
Lau, Carolin ;
Brozik, Susan ;
Atanassov, Plamen ;
Banta, Scott .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (48) :19262-19265
[9]   Direct electrochemistry of glucose oxidase immobilized on carbon nanotube for improving glucose sensing [J].
Hyun, Kyuhwan ;
Han, Sang Won ;
Koh, Won-Gun ;
Kwon, Yongchai .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (05) :2199-2206
[10]   Glucose Oxidase-graphene-chitosan modified electrode for direct electrochemistry and glucose sensing [J].
Kang, Xinhuang ;
Wang, Jun ;
Wu, Hong ;
Aksay, Ilhan A. ;
Liu, Jun ;
Lin, Yuehe .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) :901-905