Real-Time 2-D Temperature Imaging Using Ultrasound

被引:133
作者
Liu, Dalong [2 ]
Ebbini, Emad S. [1 ]
机构
[1] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
GPU; HIFU; image-guided surgery; therapeutic ultrasound; NONINVASIVE ESTIMATION; TISSUE TEMPERATURE;
D O I
10.1109/TBME.2009.2035103
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have previously introduced methods for noninvasive estimation of temperature change using diagnostic ultrasound. The basic principle was validated both in vitro and in vivo by several groups worldwide. Some limitations remain, however, that have prevented these methods from being adopted in monitoring and guidance of minimally invasive thermal therapies, e. g., RF ablation and high-intensity-focused ultrasound (HIFU). In this letter, we present first results from a real-time system for 2-D imaging of temperature change using pulse-echo ultrasound. The front end of the system is a commercially available scanner equipped with a research interface, which allows the control of imaging sequence and access to the RF data in real time. A high-frame-rate 2-D RF acquisition mode, M2D, is used to capture the transients of tissue motion/deformations in response to pulsed HIFU. The M2D RF data is streamlined to the back end of the system, where a 2-D temperature imaging algorithm based on speckle tracking is implemented on a graphics processing unit. The real-time images of temperature change are computed on the same spatial and temporal grid of the M2D RF data, i.e., no decimation. Verification of the algorithm was performed by monitoring localized HIFU-induced heating of a tissue-mimicking elastography phantom. These results clearly demonstrate the repeatability and sensitivity of the algorithm. Furthermore, we present in vitro results demonstrating the possible use of this algorithm for imaging changes in tissue parameters due to HIFU-induced lesions. These results clearly demonstrate the value of the real-time data streaming and processing in monitoring, and guidance of minimally invasive thermotherapy.
引用
收藏
页码:12 / 16
页数:5
相关论文
共 13 条
[1]   Noninvasive estimation of tissue temperature via high-resolution spectral analysis techniques [J].
Amini, AN ;
Ebbini, ES ;
Georgiou, TT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (02) :221-228
[2]   Dual-mode ultrasound phased arrays for image-guided surgery [J].
Ebbini, Emad S. ;
Yao, Hui ;
Shrestha, Ajay .
ULTRASONIC IMAGING, 2006, 28 (02) :65-82
[3]  
Ebbini ES, 2006, I S BIOMED IMAGING, P884
[4]  
Kinsler L.. E., 2000, FUNDAMENTALS ACOUSTI
[5]   Noninvasive temperature estimation in tissue via ultrasound echo-shifts .1. Analytical model [J].
MaassMoreno, R ;
Damianou, CA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 100 (04) :2514-2521
[6]   Fundamental limitations of noninvasive temperature imaging by means of ultrasound echo strain estimation [J].
Miller, NR ;
Bamber, JC ;
Meaney, PM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (10) :1319-1333
[7]   On the feasibility of remote palpation using acoustic radiation force [J].
Nightingale, KR ;
Palmeri, ML ;
Nightingale, RW ;
Trahey, GE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 110 (01) :625-634
[8]  
Pernot M, 2004, IEEE T ULTRASON FERR, V51, P606, DOI 10.1109/TUFFC.2004.1308695
[9]  
Rajagopalan B., 1979, Ultrasonic Tissue Characterisation II, P227
[10]   NONINVASIVE ESTIMATION OF TISSUE TEMPERATURE RESPONSE TO HEATING FIELDS USING DIAGNOSTIC ULTRASOUND [J].
SEIP, R ;
EBBINI, ES .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (08) :828-839