Influence of the Compliance of the Neck Arteries and Veins on the Measurement of Intracranial Volume Change by Phase-Contrast MRI

被引:20
作者
Tain, Rong-Wen [1 ]
Ertl-Wagner, Birgit [2 ]
Alperin, Noam [1 ]
机构
[1] Univ Miami, Dept Radiol & Biomed Engn, Miami, FL 33136 USA
[2] Univ Munich, Inst Clin Radiol, D-80539 Munich, Germany
关键词
intracranial volume change; cerebral arterial inflow and venous outflow; phase contrast magnetic resonance imaging; vascular compliance; CEREBROSPINAL-FLUID; PRESSURE; ELASTANCE;
D O I
10.1002/jmri.21925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the influence of arterial and venous vascular compliances in the neck region on the measurement of the change in intracranial volume during the cardiac cycle. Materials and Methods: Arterial and venous blood flows were imaged by MRI phase contrast at two different locations, one close to the skull base (upper) and one 2-3 cm lower, around C3 level (lower). Maximal intracranial volume change (ICVC) measurements were derived from the momentary difference between the arterial inflow and venous outflow rates at the upper and lower locations separately to assess the influence of the compliances of the vessel segments bounded by the two different imaging locations. Imaging location for the craniospinal cerebrospinal fluid flow was a constant variable in this experiment. Results: The systolic ICVC obtained using the lower location was consistently larger than when using the upper location. Comparison between arterial and venous flow dynamics revealed a much larger changes in flow dynamic and lumen areas in the veins compared with the arteries, which explain the large venous influence on the intracranial volume change measurement. Conclusion: Arterial inflow and venous outflow should be sampled at a level close to the skull base (C1-C2) to minimize the influence of the compliance of arteries and the collapsibility of veins for a reliable measurement of ICVC.
引用
收藏
页码:878 / 883
页数:6
相关论文
共 12 条
[1]   From cerebrospinal fluid pulsation to noninvasive intracranial compliance and pressure measured by MRI flow studies [J].
Alperin, N ;
Mazda, M ;
Lichtor, T ;
Lee, SH .
CURRENT MEDICAL IMAGING REVIEWS, 2006, 2 (01) :117-129
[2]   PUBS: Pulsatility-based segmentation of lumens conducting non-steady flow [J].
Alperin, N ;
Lee, SH .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :934-944
[3]   Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI [J].
Alperin, N ;
Vikingstad, EM ;
GomezAnson, B ;
Levin, DN .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :741-754
[4]   MR-intracranial pressure (ICP): A method to measure intracranial elastance and pressure noninvasively by means of MR imaging: Baboon and human study [J].
Alperin, NJ ;
Lee, SH ;
Loth, F ;
Raksin, PB ;
Lichtor, T .
RADIOLOGY, 2000, 217 (03) :877-885
[5]   Relationship between cerebrospinal fluid and blood dynamics in healthy volunteers and patients with communicating hydrocephalus [J].
Balédent, O ;
Gondry-Jouet, C ;
Meyer, ME ;
De Marco, G ;
Le Gars, D ;
Henry-Feugeas, MC ;
Idy-Peretti, I .
INVESTIGATIVE RADIOLOGY, 2004, 39 (01) :45-55
[6]  
Beards SC, 1998, ANAESTHESIA, V53, P627
[7]  
DHOONDIA H, 2003, P 11 ANN M ISMRM TOR
[8]   Early experience from the application of a noninvasive magnetic resonance imaging-based measurement of intracranial pressure in hydrocephalus [J].
Glick, Roberta P. ;
Niebruegge, Josh ;
Lee, Sang H. ;
Egibor, Osbert ;
Lichtor, Terry ;
Alperin, Noam .
NEUROSURGERY, 2006, 59 (05) :1052-1060
[9]  
Kim J, 2007, AM J NEURORADIOL, V28, P983
[10]   Interrelationship between non-invasive measurements of atherosclerosis: flow-mediated dilation of brachial artery, carotid intima-media thickness and pulse wave velocity [J].
Kobayashi, K ;
Akishita, M ;
Yu, W ;
Hashimoto, M ;
Ohni, M ;
Toba, K .
ATHEROSCLEROSIS, 2004, 173 (01) :13-18