Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap

被引:3
作者
Neves, Filipe Sousa [1 ]
Braga, Joana [1 ]
Sepulveda, Paula [1 ]
Bilhoto, Miguel [1 ]
机构
[1] Ctr Hosp Vila Nova de Gaia Espinho, Dept Ophthalmol, Rua Conceicao Fernandes, P-4434502 Vila Nova De Gaia, Portugal
来源
CASE REPORTS IN OPHTHALMOLOGY | 2019年 / 10卷 / 02期
关键词
Retinal detachment; Macular hole; Myopia; Autologous neurosensory retinal free flap; MANAGEMENT; TRANSPLANTATION; BLOOD;
D O I
10.1159/000500275
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this case report is to describe a modified technique involving the use of an autologous neurosensory retinal free flap for closure of a macular hole (MH) during retinal detachment (RD) surgery. A 50-year-old female presented with sudden vision loss (light perception only) and a recurrent myopic RD associated with an MH. An autologous neurosensory retinal free flap was obtained and moved toward the MH. Silicone oil was used as an endotamponade and removed after 6 months. Two months after oil removal visual acuity improved to 20/400 and remained stable thereafter; however, the patient developed central retinal atrophy. One year after surgery the MH was closed and the retina attached. This modified technique with the use of an autologous neurosensory retinal flap provides an alternative approach for recurrent MH in RD procedures. (c) 2019 The Author(s) Published by S. Karger AG, Basel
引用
收藏
页码:160 / 164
页数:5
相关论文
共 10 条
  • [1] Autologous neurosensory retinal free patch transplantation for persistent full-thickness macular hole
    De Giacinto, Chiara
    D'Aloisio, Rossella
    Cirigliano, Gabriella
    Pastore, Marco Rocco
    Tognetto, Daniele
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (05) : 1147 - 1150
  • [2] Ding C, 2018, OPHTHALMIC RES, V22, P1
  • [3] Autologous Neurosensory Retinal Free Flap for Closure of Refractory Myopic Macular Holes
    Grewal, Dilraj S.
    Mahmoud, Tamer H.
    [J]. JAMA OPHTHALMOLOGY, 2016, 134 (02) : 229 - 230
  • [4] Management of refractory macular hole with blood and gas-assisted autologous neurosensory retinal free flap transplantation: a case report
    Liu, Pei-Kang
    Chang, Yo-Chen
    Wu, Wen-Chuan
    [J]. BMC OPHTHALMOLOGY, 2018, 18
  • [5] INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR SURGICAL REPAIR OF MYOPIC MACULAR HOLES
    Michalewska, Zofia
    Michalewski, Janusz
    Dulczewska-Cichecka, Karolina
    Nawrocki, Jerzy
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (04): : 664 - 669
  • [6] SURGICAL MANAGEMENT OF RETINAL DETACHMENT BECAUSE OF MACULAR HOLE IN HIGHLY MYOPIC EYES
    Ortisi, Elina
    Avitabile, Teresio
    Bonfiglio, Vincenza
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (09): : 1704 - 1718
  • [7] AUTOLOGOUS LENS CAPSULAR FLAP TRANSPLANTATION COMBINED WITH AUTOLOGOUS BLOOD APPLICATION IN THE MANAGEMENT OF REFRACTORY MACULAR HOLE
    Peng, Jie
    Chen, Chunli
    Jin, Haiying
    Zhang, Hongtao
    Zhao, Peiquan
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (11): : 2177 - 2183
  • [8] Features Involved in the Healing Process of Macular Holes
    Pertile, Grazia
    Mete, Maurizio
    Alfano, Alessandro
    [J]. JAMA OPHTHALMOLOGY, 2017, 135 (08) : 833 - 834
  • [9] THE CURRENT SURGICAL MANAGEMENT OF LARGE, RECURRENT, OR PERSISTENT MACULAR HOLES
    Tam, Alex L. C.
    Yan, Peng
    Gan, Nicola Y.
    Lam, Wai-Ching
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (07): : 1263 - 1275
  • [10] Inverted ILM flap, free ILM flap and conventional ILM peeling for large macular holes
    Velez-Montoya R.
    Ramirez-Estudillo J.A.
    de Liano C.S.-G.
    Bejar-Cornejo F.
    Sanchez-Ramos J.
    Guerrero-Naranjo J.L.
    Morales-Canton V.
    Hernandez-Da Mota S.E.
    [J]. International Journal of Retina and Vitreous, 4 (1)