摘要
A hydrogenated amorphous silicon photodiode is used for the integrated, real-time detection of chemiluminescent reactions in solution. The light emission at 425 nm, resulting from the horseradish peroxidase-catalyzed oxidation of luminol, is detected by a p-i-n amorphous silicon photodiode operated at zero bias. The sensitivity achieved is in the range of nanomole of horseradish peroxidase per liter.
引用
收藏
页码:415 / 416
页数:2
相关论文
共 10 条
[1]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[2]   Microfluidic biosensing systems -: Part I.: Development and optimisation of enzymatic chemiluminescent μ-biosensors based on silicon microchips [J].
Davidsson, R ;
Genin, F ;
Bengtsson, M ;
Laurell, T ;
Emnéus, J .
LAB ON A CHIP, 2004, 4 (05) :481-487
[3]   An on-chip thin film photodetector for the quantification of DNA probes and targets in microarrays [J].
Fixe, F ;
Chu, V ;
Prazeres, DMF ;
Conde, JP .
NUCLEIC ACIDS RESEARCH, 2004, 32 (09) :e70
[4]   CMOS chip as luminescent sensor for biochemical reactions [J].
Lu, U ;
Hu, BCP ;
Shih, YC ;
Yang, YS ;
Wu, CY ;
Yuan, CJ ;
Ker, MD ;
Wu, TK ;
Li, YK ;
Hsieh, YZ ;
Hsu, WY ;
Lin, CT .
IEEE SENSORS JOURNAL, 2003, 3 (03) :310-316
[5]   Opto-electronic DNA chip: high performance chip reading with an all-electric interface [J].
Mallard, F ;
Marchand, G ;
Ginot, F ;
Campagnolo, R .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (09) :1813-1820
[6]   Monolithic integrated optical detection for microfluidic systems using thin film photodiodes based on amorphous silicon [J].
Schaefer, H ;
Seibel, K ;
Walder, M ;
Schoeler, L ;
Pletzer, T ;
Waidelich, M ;
Ihmels, H ;
Ehrhardt, D ;
Boehm, M .
MEMS 2005 Miami: Technical Digest, 2005, :758-761
[7]  
Street R.a., 1991, Hydrogenated amorphous silicon
[8]  
THORPE GHG, 1985, CLIN CHEM, V31, P1335
[9]   Monolithic capillary electrophoresis device with integrated fluorescence detector [J].
Webster, JR ;
Burns, MA ;
Burke, DT ;
Mastrangelo, CH .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1622-1626
[10]   Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection [J].
Yakovleva, J ;
Davidsson, R ;
Lobanova, A ;
Bengtsson, M ;
Eremin, SA ;
Laurell, T ;
Emnéus, J .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :2994-3004