Development of backgammon-type multiwire proportional counters for the detection of x rays

被引:9
作者
Kimpton, J. A. [1 ]
Kinnane, M. N. [1 ]
Chantler, C. T. [1 ]
机构
[1] Univ Melbourne, Sch Phys, Parkville, Vic 3010, Australia
基金
澳大利亚研究理事会;
关键词
D O I
10.1063/1.2237760
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A multiwire proportional counter (MWPC) based on a backgammon-type design has been developed for the detection of x-ray photons in two dimensions over the energy range of 4-6 keV. The MWPC was designed for operation in an experimental spectroscopy application requiring single photon counting over a wide range of count rates, high photon detection efficiency and resolution, and a highly linear response function across the detector face. A model based on attenuation of the incident x-ray beam by the various components of the detector is presented and highlights key areas for efficiency optimization. The design, construction, testing procedure, and performance of the backgammon MWPC are presented and all objectives are met including a particularly impressive differential nonlinearity. (c) 2006 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 50 条
[31]   DEVELOPMENT OF A MULTIWIRE PROPORTIONAL CHAMBER AS AN AREA SENSITIVE DETECTOR FOR X-RAY PROTEIN CRYSTALLOGRAPHY. [J].
Bade, D. ;
Parak, F. ;
Moessbauer, R.L. ;
Hoppe, W. ;
Levai, N. ;
Charpak, G. .
Nuclear Instruments & Methods in Physics Research, 1980, 201 (01) :193-196
[32]   DETECTION OF SOFT X-RAYS WITH A XENON PROPORTIONAL SCINTILLATION-COUNTER [J].
POLICARPO, AJ ;
ALVES, MAF ;
SALETE, M ;
LEITE, SCP ;
DOSSANTO.MC .
NUCLEAR INSTRUMENTS & METHODS, 1974, 118 (01) :221-226
[33]   Xenon-Neon gas proportional-scintillation counters for x rays below 2 keV: Experimental results [J].
Borges, FIGM ;
Santos, FP ;
dos Santos, JMF ;
Dias, THVT ;
Rachinhas, PJBM ;
Conde, CAN .
2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, :181-185
[34]   Development of digital X-ray image sensor using a two-dimensional multiwire proportional chamber [J].
Lee, DM ;
Park, JB ;
Kim, DS ;
Kang, HD .
SENSORS AND MATERIALS, 1996, 8 (08) :523-534
[35]   Xenon-neon gas proportional-scintillation counters for X-rays below 2 keV: Experimental results [J].
Borges, FIGM ;
Santos, FP ;
dos Santos, JMF ;
Dias, THVT ;
Rachinhas, PJBM ;
Conde, CAN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) :842-846
[36]   The energy resolution of xenon-neon filled gas proportional-scintillation counters for x-rays below 2 keV [J].
Borges, FIGM ;
Santos, FP ;
Dias, THVT ;
Rachinhas, PJBM ;
Conde, CAN ;
Stauffer, AD .
2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, :294-297
[37]   MULTIWIRE PROPORTIONAL CHAMBER USING NEW-TYPE DELAY-LINES AND ITS APPLICATIONS TO X-RAY-DIFFRACTION [J].
IZUMI, T .
JAPANESE JOURNAL OF APPLIED PHYSICS, 1975, 14 (10) :1581-1584
[38]   AN IMAGING GAS SCINTILLATION PROPORTIONAL COUNTER FOR THE DETECTION OF SUBKILOELECTRON-VOLT X-RAYS [J].
HAILEY, CJ ;
KU, WHM ;
VARTANIAN, MH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) :138-141
[39]   Xenon-neon gas proportional-scintillation counters for X-rays below 2 keV: A Monte Carlo simulation study [J].
Borges, FIGM ;
Santos, FP ;
Dias, THVT ;
Rachinhas, PJBM ;
Conde, CAN ;
Stauffer, AD .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) :917-922
[40]   ESCAPE OF CHARACTERISTIC X-RAYS FROM XE-FILLED PROPORTIONAL COUNTERS AND ITS EFFECT ON IN-VIVO MEASUREMENTS OF PU-AM [J].
YANIV, SS ;
BRODSKY, A ;
SASHIN, D .
HEALTH PHYSICS, 1970, 19 (01) :69-+