Development of backgammon-type multiwire proportional counters for the detection of x rays

被引:9
|
作者
Kimpton, J. A. [1 ]
Kinnane, M. N. [1 ]
Chantler, C. T. [1 ]
机构
[1] Univ Melbourne, Sch Phys, Parkville, Vic 3010, Australia
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2006年 / 77卷 / 08期
基金
澳大利亚研究理事会;
关键词
D O I
10.1063/1.2237760
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A multiwire proportional counter (MWPC) based on a backgammon-type design has been developed for the detection of x-ray photons in two dimensions over the energy range of 4-6 keV. The MWPC was designed for operation in an experimental spectroscopy application requiring single photon counting over a wide range of count rates, high photon detection efficiency and resolution, and a highly linear response function across the detector face. A model based on attenuation of the incident x-ray beam by the various components of the detector is presented and highlights key areas for efficiency optimization. The design, construction, testing procedure, and performance of the backgammon MWPC are presented and all objectives are met including a particularly impressive differential nonlinearity. (c) 2006 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Optimisation of the spatial linearity in backgammon-type multi-wire gas proportional counters-The relevance of charge cloud distribution
    Payne, A. T.
    Kimpton, J. A.
    Smale, L. F.
    Chantler, C. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 190 - 197
  • [2] Compact multiwire proportional counters for the detection of fission fragments
    Jhingan, Akhil
    Sugathan, P.
    Golda, K. S.
    Singh, R. P.
    Varughese, T.
    Singh, Hardev
    Behera, B. R.
    Mandal, S. K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (12):
  • [3] Basic performance of a pressurized backgammon-type position-sensitive proportional counter for thermal neutrons
    Horiguchi, T
    Itoh, T
    Ito, S
    Yamamoto, T
    Miyasaka, T
    Sakai, J
    Shibata, K
    Masuda, Y
    Okumura, A
    Niwa, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 529 (1-3): : 369 - 372
  • [4] POINT ANODE PROPORTIONAL COUNTERS FOR DETECTION OF SOFT X RAYS IN MICROANALYSIS
    RANZETTA, GV
    SCOTT, VD
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1967, 44 (12): : 983 - &
  • [5] X-RAY AND GAMMA-IMAGING WITH MULTIWIRE PROPORTIONAL-COUNTERS
    BATEMAN, JE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (01): : 131 - 141
  • [6] POSITION-SENSITIVE MULTIWIRE PROPORTIONAL-COUNTERS FOR X-RAY ASTRONOMY
    UBERTINI, P
    SPACE SCIENCE REVIEWS, 1987, 46 (1-2) : 1 - 29
  • [7] Simulation and minimization of nonlinear effects in backgammon- type multi-wire gas proportional counters
    Payne, A. T.
    Kimpton, J. A.
    Kinnane, M. N.
    Chantler, C. T.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (02)
  • [8] PROPORTIONAL COUNTERS AND ELECTRONIC SYSTEMS FOR OBSERVING COSMIC X-RAYS
    CHODIL, G
    MARK, H
    RODRIGUES, RM
    ROWE, C
    SWIFT, CD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (10): : 1508 - +
  • [9] THE CALIBRATION OF PROPORTIONAL COUNTERS WITH X-RAYS PRODUCED BY RADIOACTIVE SOURCES
    ROTHWELL, P
    WEST, D
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION A, 1950, 63 (365): : 541 - 543
  • [10] MULTIWIRE PROPORTIONAL COUNTER FOR SOFT-X-RAY DETECTION
    KALLNE, J
    KALLNE, E
    ATENCIO, LG
    MORRIS, CL
    THOMPSON, AC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 203 (1-3): : 415 - 418