Phase current reconstruction for ac motor drives using a dc link single current sensor and measurement voltage vectors

被引:133
作者
Kim, Hongrae [1 ]
Jahns, Thomas M.
机构
[1] Ford Motor Co, Elect Machine Dr Syst Dept, Dearborn, MI 48120 USA
[2] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
基金
欧洲研究理事会; 美国国家科学基金会;
关键词
measurement vector insertion method (MVIM);
D O I
10.1109/TPEL.2006.880262
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three-phase current measurement using only a single current sensor in the inverter dc link is appealing for ac motor drives because it minimizes the number of current sensors, thereby reducing sensor cost, weight, and volume. However, the basic dc link single current sensor technique poses special challenges because the duration of the active voltage vectors must be long enough to measure the dc link current reliably during every pulsewidth modulation switching interval. A new single current sensor algorithm for reconstructing the phase currents called the measurement vector insertion method (MVIM) is presented that overcomes this problem using active voltage vectors that are applied for brief measurement intervals only when needed during each. fundamental frequency cycle. The insertion of measurement vectors makes it possible to reconstruct the output phase currents with minimum impact on the machine's performance and operating envelope. A combination of analytical and experimental results is provided to confirm that the MVIM algorithm offers attractive phase current reconstruction performance in comparison to alternative dc link single current sensor algorithms.
引用
收藏
页码:1413 / 1419
页数:7
相关论文
共 12 条
[1]   Single current sensor technique in the DC link of three-phase PWM-VS inverters: A review and a novel solution [J].
Blaabjerg, F ;
Pedersen, JK ;
Jaeger, U ;
Thoegersen, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (05) :1241-1253
[2]  
Blaabjerg F., 1994, P 5 INT C POW EL VAR, P26
[3]  
BOYS JT, 1988, P I ELECT ENG B, V135, P27
[4]  
FRENCH CD, 1993, P 5 EUR C POW EL APP, P7
[5]   DERIVATION OF MOTOR LINE-CURRENT WAVEFORMS FROM THE DC-LINK CURRENT OF AN INVERTER [J].
GREEN, TC ;
WILLIAMS, BW .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1989, 136 (04) :196-204
[6]  
KAVANAGH RC, 1988, P 3 INT C POW EL VAR, P13
[7]   AC voltage and current sensorless control of three-phase PWM rectifiers [J].
Lee, DC ;
Lim, DS .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (06) :883-890
[8]   A novel control method for three-phase PWM rectifiers using a single current sensor [J].
Lee, WC ;
Hyun, DS ;
Lee, TK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (05) :861-870
[9]  
MOYNIHAN JF, 1991, P 4 EUR C POW EL APP, P3
[10]  
Riese M., 1996, POW CONV INT MOT C P