Edwards FloTrac™ sensor and Vigileo™ monitor:: easy, accurate, reliable cardiac output assessment using the arterial pulse wave

被引:126
作者
Manecke, Gerard R. [1 ]
机构
[1] Univ Calif San Diego, Med Ctr, San Diego, CA 92103 USA
关键词
arterial pressure wave; arterial pulse analysis; cardiac output;
D O I
10.1586/17434440.2.5.523
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Edwards Lifesciences has recently introduced the FloTraC(TM) sensor and Vigileo(TM) monitor system for monitoring cardiac output continuously. It does not require thermodilution or dye dilution, but rather bases its calculations on arterial waveform characteristics in conjunction with patient demographic data. It is unique among arterial waveform cardiac output systems in that it does not require calibration with another method. Studies thus far indicate that it is robust and accurate over a wide range of cardiac output and clinical conditions. It will be valuable in the care of many patients, such as those with critical illness, cardiovascular dysfunction, trauma or undergoing major surgery.
引用
收藏
页码:523 / 527
页数:5
相关论文
共 16 条
  • [1] Abreu Alexandre R, 2004, J Intensive Care Med, V19, P291, DOI 10.1177/0885066604265255
  • [2] Bossert T, 2000, Z KARDIOL, V89, P54, DOI 10.1007/s003920050009
  • [3] BROCKUTNE JG, 1984, S AFR MED J, V66, P451
  • [4] Della Rocca G, 2003, CAN J ANAESTH, V50, P707
  • [5] Continuous and intermittent cardiac output measurement:: pulmonary artery catheter versus aortic transpulmonary technique
    Della Rocca, G
    Costa, MG
    Pompei, L
    Coccia, C
    Pietropaoli, P
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (03) : 350 - 356
  • [6] COMPARISON OF AORTIC PULSE-WAVE CONTOUR ANALYSIS AND THERMODILUTION METHODS OF MEASURING CARDIAC-OUTPUT DURING ANESTHESIA IN THE DOG
    ENGLISH, JB
    HODGES, MR
    SENTKER, C
    JOHANSEN, R
    STANLEY, TH
    [J]. ANESTHESIOLOGY, 1980, 52 (01) : 56 - 61
  • [7] Hamilton TT, 2002, ANN THORAC SURG, V74, pS1408
  • [8] Entrapment of pulmonary artery catheter in a suture at the inferior vena cava cannulation site
    Huang, L
    Elsharydah, A
    Nawabi, A
    Cork, RC
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2004, 16 (07) : 557 - 559
  • [9] COMPARISON OF CARDIAC OUTPUT BY THE DIRECT FICK AND PRESSURE PULSE CONTOUR METHODS IN THE OPEN-CHEST DOG
    HUGGINS, RA
    SMITH, EL
    SINCLAIR, MA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1949, 159 (02): : 385 - 388
  • [10] A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
    Jansen, JRC
    Schreuder, JJ
    Mulier, JP
    Smith, NT
    Settels, JJ
    Wesseling, KH
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) : 212 - 222