System of Systems Based Security-Constrained Unit Commitment Incorporating Active Distribution Grids

被引:170
作者
Kargarian, Amin [1 ]
Fu, Yong [1 ]
机构
[1] Mississippi State Univ, Dept Elect & Comp Engn, Mississippi State, MS 39762 USA
基金
美国国家科学基金会;
关键词
Active distribution grid; decentralized optimization; security-constrained unit commitment; system of systems; THERMAL UNIT; OPERATION; MODEL;
D O I
10.1109/TPWRS.2014.2307863
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In restructured power systems, the transmission and distribution grids are autonomously utilized by independent system operator (ISO) and distribution companies (DISCOs), respectively. As the operating condition of one grid influences the decisions made by operators of other grids, the ISO and DISCOs should collaborate and cooperate with each other in order to operate the entire power system in a secure and economic manner. According to the concept of system of systems (SoS) engineering, this paper presents a decentralized decision-making framework to determine a secure and economical hourly generation schedule for a transmission system encompassing numbers of active distribution grids. Taking into consideration the physical connections and shared information between ISO and DISCOs, an SoS-based SCUC framework is designed and a hierarchical optimization algorithm is presented to find optimal operating points of all independent systems in the SoS-based power system architecture. The numerical results show the effectiveness of the proposed SoS framework and solution methodology.
引用
收藏
页码:2489 / 2498
页数:10
相关论文
共 22 条
[1]  
[Anonymous], 2009, Microgrids and Active Distribution Networks
[2]  
[Anonymous], 2003, NONLINEAR PROGRAMMIN
[3]  
[Anonymous], 2011, Integration of Distributed Generation In The Power System
[4]   Optimal response of a thermal unit to an electricity spot market [J].
Arroyo, JM ;
Conejo, AJ .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (03) :1098-1104
[5]   A computationally efficient mixed-integer linear formulation for the thermal unit commitment problem [J].
Carrion, Miguel ;
Arroyo, Jose M. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (03) :1371-1378
[6]   Coordination between mid-term maintenance outage decisions and short-term security-constrained scheduling in smart distribution systems [J].
Fotouhi Ghazvini, M. A. ;
Morais, Hugo ;
Vale, Zita .
APPLIED ENERGY, 2012, 96 :281-291
[7]   Security-constrained unit commitment with AC constraints [J].
Fu, Y ;
Shahidehpour, M ;
Li, ZY .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (03) :1538-1550
[8]   Fast SCUC for large-scale power systems [J].
Fu, Yong ;
Shahidehpour, Mohammad .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (04) :2144-2151
[9]   Integrated day-ahead and hour-ahead operation model of discos in retail electricity markets considering DGs and CO2 emission penalty cost [J].
Ghadikolaei, Hadi Moghimi ;
Tajik, Elham ;
Aghaei, Jamshid ;
Charwand, Mansour .
APPLIED ENERGY, 2012, 95 :174-185
[10]   Reliability constrained unit commitment in smart grid environment [J].
Goleijani, S. ;
Ghanbarzadeh, T. ;
Nikoo, F. Sadeghi ;
Moghaddam, M. Parsa .
ELECTRIC POWER SYSTEMS RESEARCH, 2013, 97 :100-108