Determination of microcystins, nodularin, anatoxin-a, cylindrospermopsin, and saxitoxin in water and fish tissue using isotope dilution liquid chromatography tandem mass spectrometry

被引:59
|
作者
Haddad, Samuel P. [1 ]
Bobbitt, Jonathan M. [2 ]
Taylor, Raegyn B. [2 ]
Lovin, Lea M. [1 ]
Conkle, Jeremy L. [3 ]
Chambliss, C. Kevin [1 ,2 ]
Brooks, Bryan W. [1 ,4 ]
机构
[1] Baylor Univ, Ctr Reservoir & Aquat Syst Res, Dept Environm Sci, Waco, TX 76798 USA
[2] Baylor Univ, Dept Chem & Biochem, Waco, TX 76798 USA
[3] Texas A&M Univ, Dept Phys & Environm Sci, Corpus Christi, TX 78412 USA
[4] Baylor Univ, Inst Biomed Studies, Waco, TX 76798 USA
基金
美国国家卫生研究院; 美国农业部;
关键词
RPLC; HILIC; Nontarget analysis; Harmful algal bloom; Water quality; Food safety; SOLID-PHASE EXTRACTION; HARMFUL ALGAL BLOOMS; LC-MS/MS METHOD; CYANOBACTERIAL TOXINS; CYANOTOXINS; SURVEILLANCE; TOXICITY; HEALTH; THREAT;
D O I
10.1016/j.chroma.2019.03.066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cyanobacteria can form dense blooms under specific environmental conditions, and some species produce secondary metabolites known as cyanotoxins, which present significant risks to public health and the environment. Identifying toxins produced by cyanobacteria present in surface water and fish is critical to ensuring high quality food and water for consumption, and protectionn of recreational uses. Current analytical screening methods typically focus on one class of cyanotoxins in a single matrix and rarely include saxitoxin. Thus, a cross-class screening method for microcystins, nodularin, anatoxin-a, cylindrospermopsin, and saxitoxin was developed to examine target analytes in environmental water and fish tissue. This was done, due to the broad range of cyanotoxin physicochemical properties, by pairing two extraction and separation techniques to improve isolation and detection. For the first time a zwitterionic hydrophilic interaction liquid chromatography column was evaluated to separate anatoxin-a, cylindrospermopsin, and saxitoxin, demonstrating greater sensitivity for all three compounds over previous techniques. Further, the method for microcystins, nodularin, anatoxin-a, and cylindrospermopsin were validated using isotopically labeled internal standards, again for the first time, resulting in improved compensation for recovery bias and matrix suppression. Optimized extractions for water and fish tissue can be extended to other congeners in the future. These improved separation and isotope dilution techniques are a launching point for more complex, non-targeted analyses, with preliminary targeted screening. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 74
页数:9
相关论文
共 50 条
  • [41] Accurate determination of selected pesticides in soya beans by liquid chromatography coupled to isotope dilution mass spectrometry
    Perez, J. F. Huertas
    Sejeroe-Olsen, B.
    Fernandez Alba, A. R.
    Schimmel, H.
    Dabrio, M.
    TALANTA, 2015, 137 : 120 - 129
  • [42] Ultra trace determination of fluorobenzoic acids in reservoir and ground water using isotope dilution gas chromatography mass spectrometry
    Mueller, Karsten
    Seubert, Andreas
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2014, 50 (02) : 277 - 284
  • [43] Simultaneous determination of 16 organophosphorus flame retardants and plasticizers in fish by liquid chromatography-tandem mass spectrometry
    Santin, G.
    Eljarrat, E.
    Barcelo, D.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1441 : 34 - 43
  • [44] Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry
    van der Lijke, Henk
    Alffenaar, Jan-Willem C.
    Kok, Wim Th.
    Greijdanus, Ben
    Uges, Donald R. A.
    TALANTA, 2012, 88 : 385 - 390
  • [45] Multi-residue determination of antibiotics in fish by liquid chromatography-tandem mass spectrometry
    Gbylik, M.
    Posyniak, A.
    Mitrowska, K.
    Bladek, T.
    Zmudzki, J.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (06): : 940 - 948
  • [46] Effectiveness of different cleanup sorbents for the determination of avermectins in fish by liquid chromatography tandem mass spectrometry
    Rafidah, I.
    Ghanthimathi, S.
    Fatimah, A. B.
    Mahyudin, N. A.
    ANALYTICAL METHODS, 2013, 5 (16) : 4172 - 4178
  • [47] Development and validation of a pressurized liquid extraction liquid chromatography-tandem mass spectrometry method for perfluorinated compounds determination in fish
    Llorca, Marta
    Farre, Marinella
    Pico, Yolanda
    Barcelo, Damia
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (43) : 7195 - 7204
  • [48] A high throughput targeted and non-targeted method for the analysis of microcystins and anatoxin-A using on-line solid phase extraction coupled to liquid chromatography-quadrupole time-of-flight high resolution mass spectrometry
    Ortiz, Xavier
    Korenkova, Eva
    Jobst, Karl J.
    MacPherson, Karen A.
    Reiner, Eric J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (21) : 4959 - 4969
  • [49] Development and validation of a stable-isotope dilution liquid chromatography-tandem mass spectrometry method for the determination of bisphenols in ready-made meals
    Regueiro, Jorge
    Wenzl, Thomas
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1414 : 110 - 121
  • [50] An optimized method for the accurate determination of patulin in apple products by isotope dilution-liquid chromatography/mass spectrometry
    Seo, Miyeong
    Kim, Byungjoo
    Baek, Song-Yee
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (18) : 5433 - 5442