Effect of internal woven roller shade and glazing on the energy and daylighting performances of an office building in the cold climate of Shillong

被引:55
作者
Singh, Ramkishore [1 ]
Lazarus, I. J. [1 ]
Kishore, V. V. N. [2 ]
机构
[1] Durban Univ Technol, Dept Phys, ZA-4001 Durban, South Africa
[2] TERI Univ, Environm & Energy Dept, New Delhi 110070, India
关键词
Energy savings; Day lighting; Visual comfort; Woven roller shades; Building energy simulation; EnergyPlus; CONTROL STRATEGIES; CONTROL-SYSTEMS; SOLAR SHADES; IMPACT; GLARE; SIMULATION; DESIGN; BLINDS; AVAILABILITY; BALLASTS;
D O I
10.1016/j.apenergy.2015.09.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The energy and visual performances of the facades are defined by many parameters including fa ade size, properties of glazings and shadings, and their arrangements as well as control strategies. In this study, a number of combinations of internal woven roller shades and four double glazings have been proposed and assessed in integrated manner in order to improve the energy efficiency and visual comfort in new or existing office buildings. Office rooms facing south, east, north and west have been simulated for cold climate, by varying glazed areas and proposed glazing and shading alternatives. Results have been calculated, compared and analyzed in terms of the energy consumptions, energy saving potentials, daylight autonomy, useful daylight illuminance and discomfort glare free time, for each of the combinations. Simulation results show that the choice of glazing and shading alternatives can have substantial impact on energy and visual performances of the office space. Regardless of fa ade orientation, the maximum energy saving is achieved for a window-to-wall ratio (WWR) of 30%. Saving potential decreases significantly for larger glazed area and for each fa ade orientation. For all fa ade orientations and glazed areas (except for 30% WWR in the north wall), a bare low-e coated double glazing (U = 1.616 W/m(2) K, SHGC = 0.209, tau(v) = 0.301) is found to be the most energy efficient choice. For 30% north glazing, the energy efficiency can be maximized with a different bare low-e coated double glazing (U = 1.628W/m(2) K, SHGC = 0.370, tau(v) = 0.581). Moreover, glare affected time, daylight autonomy and useful daylight illuminance in the office spaces with these glazing choices are estimated >= 50%, between 46% and 99% and in the range of 53-88% respectively. Also, the visual comfort can further be improved just by deploying even a highly transparent fabric (50% transmittance, 20% reflectance, 45% average openness) as an interior roller shade with these glazing choices. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:317 / 333
页数:17
相关论文
共 56 条
[11]   Development of a daylight responsive dimming system and preliminary evaluation of system performance [J].
Choi, AS ;
Sung, MK .
BUILDING AND ENVIRONMENT, 2000, 35 (07) :663-676
[12]   The characteristics of photosensors and electronic dimming ballasts in daylight responsive dimming systems [J].
Choi, AS ;
Song, KD ;
Kim, YS .
BUILDING AND ENVIRONMENT, 2005, 40 (01) :39-50
[13]  
Crawley D. B., 2001, ENERGY BUILD, V33
[14]   Influence of shading control patterns on the energy assessment of office spaces [J].
da Silva, Pedro Correia ;
Leal, Vitor ;
Andersen, Marilyne .
ENERGY AND BUILDINGS, 2012, 50 :35-48
[15]   Quantifying energy savings in daylight responsive systems: The role of dimming electronic ballasts [J].
Doulos, L. ;
Tsangrassoulis, A. ;
Topalis, F. .
ENERGY AND BUILDINGS, 2008, 40 (01) :36-50
[16]  
EnergyPlus Engineering Reference, 2013, ENERGYPLUS ENG REF E
[17]   Impact of external shading devices on thermal and daylighting performance of offices in hot climate regions [J].
Freewan, Ahmed A. Y. .
SOLAR ENERGY, 2014, 102 :14-30
[18]   Methodology to estimate building energy consumption using EnergyPlus Benchmark Models [J].
Fumo, Nelson ;
Mago, Pedro ;
Luck, Rogelio .
ENERGY AND BUILDINGS, 2010, 42 (12) :2331-2337
[19]   Impact of window blinds on daylight-linked dimming and automatic on/off lighting controls [J].
Galasiu, AD ;
Atif, MR ;
MacDonald, RA .
SOLAR ENERGY, 2004, 76 (05) :523-544
[20]   Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature review [J].
Galasiu, Anca D. ;
Veitch, Jennifer A. .
ENERGY AND BUILDINGS, 2006, 38 (07) :728-742