Experimental determination of the radial dose function of 90Sr/90Y IVBT sources

被引:12
作者
Holmes, Shannon M. [1 ]
DeWerd, Larry A. [1 ]
Micka, John A. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
IVBT; radial dose function; Sr-90; Y-90;
D O I
10.1118/1.2256068
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A series of measurements were undertaken using both high sensitivity radiochromic film and new lithium fluoride thermoluminescent dosimeters in a liquid water medium to define the radial dose function of Sr-90/Y-90 beta emitting intravascular brachytherapy sources more accurately. These measurements of a single 5 French source pellet served to verify current Monte Carlo transport models and extrapolation chamber measurements of the radial dose function, thus providing the recommended independent published measurements for g(r) of these sources. A slight deviation in the published radial dose function at depth leads the authors to recommend that treatment planning be performed using updated g(r) values from current Monte Carlo transport models verified by measurements such as those shown in this investigation. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3225 / 3233
页数:9
相关论文
共 20 条
[11]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[12]   Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55 [J].
Niroomand-Rad, A ;
Blackwell, CR ;
Coursey, BM ;
Gall, KP ;
Galvin, JM ;
McLaughlin, WL ;
Meigooni, AS ;
Nath, R ;
Rodgers, JE ;
Soares, CG .
MEDICAL PHYSICS, 1998, 25 (11) :2093-2115
[13]  
OLKA P, 2002, RADIAT PROT DOSIM, V100, P119
[14]   Thermoluminescent dosimetry of the Symmetra TM 125I model I25.S06 interstitial brachytherapy seed [J].
Patel, NS ;
Chiu-Tsao, ST ;
Williamson, JF ;
Fan, P ;
Duckworth, T ;
Shasha, D ;
Harrison, LB .
MEDICAL PHYSICS, 2001, 28 (08) :1761-1769
[15]   Dose distributions for 90Y intravascular brachytherapy sources used with balloon catheters [J].
Piessens, M ;
Reynaert, N ;
Potempa, J ;
Thierens, H ;
Wijns, W ;
Verbeke, L .
MEDICAL PHYSICS, 2002, 29 (07) :1562-1571
[16]   Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations [J].
Rivard, MJ ;
Coursey, BM ;
DeWerd, LA ;
Hanson, WF ;
Huq, MS ;
Ibbott, GS ;
Mitch, MG ;
Nath, R ;
Williamson, JF .
MEDICAL PHYSICS, 2004, 31 (03) :633-674
[17]  
SINGLA PK, 1975, THESIS U WASHINGTON
[18]   Calibration and characterization of beta-particle sources for intravascular brachytherapy [J].
Soares, CG ;
Halpern, DG ;
Wang, CK .
MEDICAL PHYSICS, 1998, 25 (03) :339-346
[19]  
White M., 2003, LAUR031019
[20]  
Zimarino Marco, 2002, Ital Heart J, V3, P256