Effects of Blood Flow on the Tip Contact Force of Cardiac Ablation Catheters

被引:3
作者
Khoshbakht, Reza [1 ]
Kheiri, Mojtaba [1 ]
Dargahi, Javad [1 ]
Hooshiar, Amir [2 ]
机构
[1] Concordia Univ, Mech Ind & Aerosp Engn Dept, Montreal, PQ, Canada
[2] McGill Univ, Dept Surg, Montreal, PQ, Canada
来源
2022 IEEE INTERNATIONAL SYMPOSIUM ON ROBOTIC AND SENSORS ENVIRONMENTS (ROSE) | 2022年
关键词
catheter; ablation; contact force; blood flow; soft robot; ATRIAL-FIBRILLATION;
D O I
10.1109/ROSE56499.2022.9977429
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Robotic Catheter Ablation is a teleoperated robotic procedure. The robotic system for this procedure has a leader-follower configuration, thus lacking direct human touch on organs and instruments. However, the sense of touch is replaced by force sensor feedback that enables surgeons to monitor the contact force between the catheter and the patient's heart. Due to the high cost of sensorized cardiac catheters, sensor-free force estimation techniques have gained momentum in the state of the art. These techniques, for the most part, neglect the effects of blood flow in the left atrium, while recent clinical evidence suggests that blood flow disturbance can affect the stability and safety of catheter tip-tissue contact. This study was aimed at identifying the mechanisms by which blood flow may compromise tip-tissue contact force and quantifying such effects systematically. To this end, first utilizing a closed-loop flow channel, we examined the effects of blood (represented by water) flow on the magnitude of the tip contact force at physiological and pathological flow rates in 3D-printed pulmonary veins. Also, five configurations of an ablation catheter were considered to investigate the combined effects of catheter deflection and positioning of the catheter tip. Our results show that the tip contact force can greatly change because of the fluid flow, e.g., up to 37% when the catheter is close to the left inferior pulmonary vein. Also, even in the absence of blood flow, the maximum contact force was observed to reduce by increasing the catheter deflection. Diminishing tip contact force was exacerbated at higher flow rates. This study provides a quantitative mechanical explanation of why robotic ablation may result in suboptimal right inferior pulmonary vein isolation.
引用
收藏
页数:7
相关论文
共 50 条
[41]   Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters [J].
Roger A. Winkle ;
Ryan Moskovitz ;
R. Hardwin Mead ;
Gregory Engel ;
Melissa H. Kong ;
William Fleming ;
Jonathan Salcedo ;
Rob A. Patrawala ;
John H. Tranter ;
Isaac Shai .
Journal of Interventional Cardiac Electrophysiology, 2018, 52 :1-8
[42]   Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters [J].
Winkle, Roger A. ;
Moskovitz, Ryan ;
Mead, R. Hardwin ;
Engel, Gregory ;
Kong, Melissa H. ;
Fleming, William ;
Salcedo, Jonathan ;
Patrawala, Rob A. ;
Tranter, John H. ;
Shai, Isaac .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 52 (01) :1-8
[43]   A Comparison of Remote Magnetic Irrigated Tip Ablation versus Manual Catheter Irrigated Tip Catheter Ablation With and Without Force Sensing Feedback [J].
Weiss, J. Peter ;
May, Heidi T. ;
Bair, Tami L. ;
Crandall, Brian G. ;
Cutler, Michael J. ;
Day, John D. ;
Osborn, Jeffrey S. ;
Mallender, Charles ;
Bunch, T. Jared .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 :S5-S10
[44]   Contact Force-Sensing versus Standard Catheters in Non-Fluoroscopic Radiofrequency Catheter Ablation of Idiopathic Outflow Tract Ventricular Arrhythmias [J].
Karkowski, Grzegorz ;
Kuniewicz, Marcin ;
Zabek, Andrzej ;
Kozluk, Edward ;
Debski, Maciej ;
Matusik, Pawel T. ;
Lelakowski, Jacek .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
[45]   Contact-Force Recovery Can Predict Cardiac Perforation during Radiofrequency Ablation [J].
Nazeri, Alireza ;
Ganapathy, Anand ;
Massumi, Ali ;
Massumi, Mehran ;
Constantine, Garth ;
Raz, Shaul ;
Razavi, Mehdi .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (09) :1129-1132
[46]   Endocardial Versus Epicardial Ventricular Radiofrequency Ablation Utility of In Vivo Contact Force Assessment [J].
Sacher, Frederic ;
Wright, Matthew ;
Derval, Nicolas ;
Denis, Arnaud ;
Ramoul, Khaled ;
Roten, Laurent ;
Pascale, Patrizzio ;
Bordachar, Pierre ;
Ritter, Philippe ;
Hocini, Meleze ;
Dos Santos, Pierre ;
Haissaguerre, Michel ;
Jais, Pierre .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (01) :144-150
[47]   Persistent Atrial Fibrillation Ablation With or Without Contact Force Sensing [J].
Hussein, Ayman A. ;
Barakat, Amr F. ;
Saliba, Walid I. ;
Tarakji, Khaldoun G. ;
Bassiouny, Mohamed ;
Baranowski, Bryan ;
Tchou, Patrick ;
Bhargava, Mandeep ;
Dresing, Thomas ;
Callahan, Thomas ;
Cantillon, Daniel ;
Kanj, Mohamed ;
Lindsay, Bruce D. ;
Wazni, Oussama M. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (05) :483-488
[48]   Combined local impedance and contact force for radiofrequency ablation assessment [J].
Garrott, Kara ;
Laughner, Jacob ;
Gutbrod, Sarah ;
Sugrue, Alan ;
Shuros, Allan ;
Sulkin, Matt ;
Yasin, Omar ;
Bush, Jamie ;
Pottinger, Nathan ;
Meyers, Jason ;
Kapa, Suraj .
HEART RHYTHM, 2020, 17 (08) :1371-1380
[49]   Factors Influencing Contact Force in Robotic Magnetic Navigation Ablation [J].
Orczykowski, Michal ;
Bak, Maciej ;
Kaczmarek, Krzysztof ;
Urbanek, Piotr ;
Robert, Bodalski ;
Dubowski, Krzysztof ;
Warminski, Grzegorz ;
Derejko, Pawel ;
Ptaszynski, Pawel ;
Sterlinski, Maciej ;
Bilinska, Maria ;
Szumowski, Lukasz .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2025, 36 (04) :855-862
[50]   Computer simulation study on the effect of electrode-tissue contact force on thermal lesion size in cardiac radiofrequency ablation [J].
Yan, Shengjie ;
Gu, Kaihao ;
Wu, Xiaomei ;
Wang, Weiqi .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) :37-48