Performance control of a spray passive down-draft evaporative cooling system

被引:15
作者
Kang, Daeho [1 ]
Strand, Richard K. [2 ]
机构
[1] CUNY, New York City Coll Technol, Dept Environm Control Technol, Brooklyn, NY 11201 USA
[2] Univ Illinois, Illinois Sch Architecture, 611 Lorado Taft Dr, Champaign, IL 61820 USA
关键词
Control; Evaporative cooling; Downdraft; Building simulation; Wind tower; Indoor environment; WIND TOWER; HOT; VENTILATION; SIMULATION; BUILDINGS;
D O I
10.1016/j.apenergy.2018.03.039
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A spray passive down-draft evaporative cooling system has been regarded as a low-energy cooling system that leads significant energy savings in the cooling of buildings. While the energy saving capability of the system has been proven, the ability to control a comfortable indoor environment is still inadequate due to strong climatic dependency. This study seeks viable solutions to advance the control competence of the system by mitigating critical problems of the system to be a reliable cooling application in the cooling of buildings. It proposes potential control strategies for the system and alternative operations. It develops a control algorithm for the proposed control strategies and implements the algorithm in EnergyPlus. A simulation analysis follows to examine the functionality of each proposed control strategy and alternative operations. The results of the simulations ascertain that a spray PDEC system with a water flow control performs better. In addition, a spray PDEC system contributes most when it operates as a secondary cooling system to abate space cooling loads and to maintain a steady thermal environment by reducing 62.1% electricity for space cooling and 47.9% water consumption in a warm-moderate climate.
引用
收藏
页码:915 / 931
页数:17
相关论文
共 41 条
[31]  
Mazidi M., 2006, WSEAS Transactions on Fluid Mechanics, V1, P959
[32]   CFD simulation of cross-ventilation in buildings using rooftop wind-catchers: Impact of outlet openings [J].
Montazeri, H. ;
Montazeri, F. .
RENEWABLE ENERGY, 2018, 118 :502-520
[33]   Refining the use of evaporation in an experimental down-draft cool tower [J].
Pearlmutter, D ;
Erell, E ;
Etzion, Y ;
Meir, IA ;
Di, H .
ENERGY AND BUILDINGS, 1996, 23 (03) :191-197
[34]  
Rosa Schiano-Phan, 2008, 25 C PASS LOW EN ARC
[35]   Review of windcatcher technologies [J].
Saadatian, Omidreza ;
Haw, Lim Chin ;
Sopian, K. ;
Sulaiman, M. Y. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (03) :1477-1495
[36]  
Thomas L.E., 2006, Australian and New Zealand Architectural Science Association Annual Conference - Challenges for Architectural Science in Changing Climates, P97
[37]  
THOMPSON TL, 1994, ENERG CONVERS MANAGE, V35, P909
[38]  
Torcellini P., 2011, NRELTP550046861
[39]  
US Department of Energy, 2017, ENERGYPLUS TEST VAL
[40]  
Wilcox S., 2008, Renewable Energy