Performance control of a spray passive down-draft evaporative cooling system

被引:15
作者
Kang, Daeho [1 ]
Strand, Richard K. [2 ]
机构
[1] CUNY, New York City Coll Technol, Dept Environm Control Technol, Brooklyn, NY 11201 USA
[2] Univ Illinois, Illinois Sch Architecture, 611 Lorado Taft Dr, Champaign, IL 61820 USA
关键词
Control; Evaporative cooling; Downdraft; Building simulation; Wind tower; Indoor environment; WIND TOWER; HOT; VENTILATION; SIMULATION; BUILDINGS;
D O I
10.1016/j.apenergy.2018.03.039
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A spray passive down-draft evaporative cooling system has been regarded as a low-energy cooling system that leads significant energy savings in the cooling of buildings. While the energy saving capability of the system has been proven, the ability to control a comfortable indoor environment is still inadequate due to strong climatic dependency. This study seeks viable solutions to advance the control competence of the system by mitigating critical problems of the system to be a reliable cooling application in the cooling of buildings. It proposes potential control strategies for the system and alternative operations. It develops a control algorithm for the proposed control strategies and implements the algorithm in EnergyPlus. A simulation analysis follows to examine the functionality of each proposed control strategy and alternative operations. The results of the simulations ascertain that a spray PDEC system with a water flow control performs better. In addition, a spray PDEC system contributes most when it operates as a secondary cooling system to abate space cooling loads and to maintain a steady thermal environment by reducing 62.1% electricity for space cooling and 47.9% water consumption in a warm-moderate climate.
引用
收藏
页码:915 / 931
页数:17
相关论文
共 41 条
[1]  
Alvarez S, P 9 PLEA C SEV SPAIN
[2]  
[Anonymous], 2010, ENERGYPLUS INP OUTP
[3]  
[Anonymous], 9012010 ANSIASHRAEIE
[4]  
ANSI/ASHRAE, 552013 ANSIASHRAE
[5]   Experimental investigation of new designs of wind towers [J].
Bahadori, M. N. ;
Mazidi, M. ;
Dehghani, A. R. .
RENEWABLE ENERGY, 2008, 33 (10) :2273-2281
[6]  
Bowman NT, 2000, INDOOR BUILT ENVIRON, V9, P284
[7]   Climatic analysis of a passive cooling technology for the built environment in hot countries [J].
Calautit, John Kaiser ;
Hughes, Ben Richard ;
Nasir, Diana S. N. M. .
APPLIED ENERGY, 2017, 186 :321-335
[8]   CFD analysis of a heat transfer device integrated wind tower system for hot and dry climate [J].
Calautit, John Kaiser ;
Hughes, Ben Richard ;
Chaudhry, Hassam Nasarullah ;
Ghani, Saud Abdul .
APPLIED ENERGY, 2013, 112 :576-591
[9]   Comparison between evaporative cooling and a heat pipe assisted thermal loop for a commercial wind tower in hot and dry climatic conditions [J].
Calautit, John Kaiser ;
Chaudhry, Hassam Nasarullah ;
Hughes, Ben Richard ;
Ghani, Saud Abdul .
APPLIED ENERGY, 2013, 101 :740-755
[10]  
Chalfoun NV, 1997, P 26 AM SOL EN SOC