Automatic CPAP titration with different self-setting devices in patients with obstructive sleep apnoea

被引:33
作者
Stammnitz, A [1 ]
Jerrentrup, A [1 ]
Penzel, T [1 ]
Peter, JH [1 ]
Vogelmeier, C [1 ]
Becker, HF [1 ]
机构
[1] Univ Marburg, Dept Resp Med, Sleep Unit, D-35033 Marburg, Germany
关键词
automatic nasal continuous positive airway pressure titration;
D O I
10.1183/09031936.04.00074304
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Autotitrating continuous positive airway pressure (CPAP) devices automatically adjust the pressure according to upper airway obstructions. The aim of this study was to compare the treatment effects of different automatic CPAP devices (AutoSet, Horizon and Virtuoso) with conventional CPAP in patients with obstructive sleep apnoea independently of financial manufacturer support. Twelve male patients with obstructive sleep apnoea were submitted to a crossover study protocol with overnight polysomnography for 6 consecutive nights. After diagnostic polysomnography, the CPAP pressure was manually titrated. Over the next 4 nights, the patients were treated with any one of the three automatic CPAP devices or fixed CPAP in random order. The apnoea/hypopnoea index on the diagnostic night was 67.3+/-21.7 events-h(-1) and was significantly reduced to 0.7+/-1.2, 3.0+/-2.9, 2.3+/-2.5 and 12.0+/-13.6 events-h(-1) with the fixed CPAP, AutoSet, Horizon and Virtuoso devices respectively. An apnoea/hypopnoea index of <5 events-h(-1), an indicator of optimal treatment, was achieved in all patients with fixed CPAP and in 10 patients using the Autoset and Horizon devices, but in only six of the 12 using the Virtuoso. The mean pressure was significantly lower with the AutoSet and Virtuoso devices, but not with the Horizon as compared to fixed CPAP. The maximum pressure was significantly higher with the Horizon. It is concluded that automatic continuous positive airway pressure devices produce a significant reduction in apnoea/hypopnoea index; however, there is considerable difference in the efficacy of the various devices.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 28 条
  • [1] American Thoracic Society Official Statement, 1994, AM J RESP CRIT CARE, V50, P1738
  • [2] Effect of nasal continuous positive airway pressure treatment on blood pressure in patients with obstructive sleep apnea
    Becker, HF
    Jerrentrup, A
    Ploch, T
    Grote, L
    Penzel, T
    Sullivan, CE
    Peter, JH
    [J]. CIRCULATION, 2003, 107 (01) : 68 - 73
  • [3] A sleep laboratory evaluation of an automatic positive airway pressure system for treatment of obstructive sleep apnea
    Behbehani, K
    Yen, FC
    Lucas, EA
    Burk, JR
    [J]. SLEEP, 1998, 21 (05) : 485 - 491
  • [4] Nasal continuous positive airway pressure treatment: Current realities and future
    BerthonJones, M
    Lawrence, S
    Sullivan, CE
    Grunstein, R
    [J]. SLEEP, 1996, 19 (09) : S131 - S135
  • [5] FEASIBILITY OF A SELF-SETTING CPAP MACHINE
    BERTHONJONES, M
    [J]. SLEEP, 1993, 16 (08) : S120 - S123
  • [6] BONNET MH, 1992, SLEEP, V15, P526
  • [7] PATHOPHYSIOLOGY OF OBSTRUCTIVE SLEEP-APNEA
    DEEGAN, PC
    MCNICHOLAS, WT
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (07) : 1161 - 1178
  • [8] FLEETHAM J, 1996, AM J RESP CRIT CARE, pA872
  • [9] Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised prospective parallel trial
    Jenkinson, C
    Davies, RJO
    Mullins, R
    Stradling, JR
    [J]. LANCET, 1999, 353 (9170) : 2100 - 2105
  • [10] Comparison of manual and automatic CPAP titration in patients with sleep apnea/hypopnea syndrome
    Lloberes, P
    Ballester, E
    Montserrat, JM
    Botifoll, E
    Ramirez, A
    Reolid, A
    Gistau, C
    RodriguezRoisin, R
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (06) : 1755 - 1758