Analysis of interpolation schemes for image deformation methods in PIV: effect of noise on the accuracy and spatial resolution

被引:74
作者
Astarita, T. [1 ]
机构
[1] Univ Naples Federico II, DETEC, I-80125 Naples, Italy
关键词
D O I
10.1007/s00348-006-0139-4
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
As testified by a previous article (Astarita and Cardone in Exp Fluids 38:233-243, 2005), a critical point that can influence significantly the accuracy of image deformation methods (IDM) for particle image velocimetry (PIV) is the interpolation scheme (IS) used in the reconstruction of deformed images. In the cited paper the effect of noise has been neglected and for this reason in this follow-up paper the influence of the IS, in the presence of noise, on both accuracy and spatial resolution is studied. Performance assessment is conducted using synthetic images with particles of Gaussian shape and with constant and sinusoidal displacement fields. Both the local and the top hat moving average approaches are investigated and the modulation transfer function, the total and bias errors have been used to evaluate the performances of IDMs for PIV applications. The results show that, when a high noise level is present in the images, the influence of the IS is less relevant than what was shown by Astarita and Cardone (Exp Fluids 38:233-243, 2005).
引用
收藏
页码:977 / 987
页数:11
相关论文
共 25 条
[1]  
Astarita T, 2005, EXP FLUIDS, V38, P233, DOI 10.1007/S00348-004-0902-3
[2]   A hybrid digital particle tracking velocimetry technique [J].
Cowen, EA ;
Monismith, SG .
EXPERIMENTS IN FLUIDS, 1997, 22 (03) :199-211
[3]   A correlation-based continuous window-shift technique to reduce the peak-locking effect in digital PIV image evaluation [J].
Gui, L ;
Wereley, ST .
EXPERIMENTS IN FLUIDS, 2002, 32 (04) :506-517
[4]  
HUANG HT, 1993, EXP FLUIDS, V15, P263
[5]   AN IMPROVED CROSS-CORRELATION TECHNIQUE FOR PARTICLE IMAGE VELOCIMETRY [J].
JAMBUNATHAN, K ;
JU, XY ;
DOBBINS, BN ;
ASHFORTHFROST, S .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (05) :507-514
[6]  
Keane R D., 1993, Flow Visualization and Image Analysis (Springer), P1, DOI DOI 10.1007/978-94-011-2690-8_1
[7]   Estimation of the accuracy of PIV treatments for turbulent flow studies by direct numerical simulation of multi-phase flow [J].
Lecordier, B ;
Demare, D ;
Vervisch, LMJ ;
Réveillon, J ;
Trinité, M .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (09) :1382-1391
[8]   Accuracy and time performance of different schemes of the local field correction PIV technique [J].
Lecuona, A ;
Nogueira, J ;
Rodríguez, PA ;
Santana, D .
EXPERIMENTS IN FLUIDS, 2002, 33 (06) :743-751
[9]  
Liao Q, 2005, EXP FLUIDS, V38, P197, DOI 10.1007/S00348-004-0899-7
[10]   Analysis and treatment of errors due to high velocity gradients in particle image velocimetry [J].
Meunier, P ;
Leweke, T .
EXPERIMENTS IN FLUIDS, 2003, 35 (05) :408-421