Three-dimensional observations of faulting process in Westerly granite under uniaxial and triaxial conditions by X-ray CT scan

被引:165
作者
Kawakata, H [1 ]
Cho, A
Kiyama, T
Yanagidani, T
Kusunose, K
Shimada, M
机构
[1] Kyoto Univ, Disaster Prevent Res Inst, Res Ctr Earthquake Predict, Kyoto 6110011, Japan
[2] Geol Survey Japan, Tsukuba, Ibaraki 3058567, Japan
[3] Mitsui Construct Co Ltd, Chiba 2700132, Japan
关键词
X-ray CT scan; faulting; three-dimensional reconstruction; stress drop; triaxial testing; uniaxial testing;
D O I
10.1016/S0040-1951(99)00205-X
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Observations of spatial fault development in granite undergoing compression provide new insights into the process of faulting. Dry intact Westerly granite samples were loaded under a confining pressure of 100 MPa (triaxial conditions) and 5 MPa (similar to uniaxial conditions), and the progress of faulting was controlled by maintaining the increment of circumferential displacement at a constant rate, which apparently stiffened the machine. The samples were unloaded after they experienced some degree of stress drop and were successfully recovered before faulting progressed further. A conventional medical X-ray CT scanning system was used to image the sample interiors. Three-dimensional fault systems were detected with sequential X-ray CT images. It was found that three-dimensional reconstruction by X-ray CT images yields not only three-dimensional images of the fault system, but also provides fault cross-section images with much less artificial noise (artifacts) than does direct X-ray CT imaging. Three-dimensional images show that a fault system that developed under uniaxial conditions is much more complicated than a fault system produced by triaxial conditions. In addition, the fault plane produced under uniaxial conditions is inclined at a lower angle to the maximum compressive axis than under triaxial conditions. Comparing X-ray CT images, we show that a fault nucleates locally on the sample surface just after peak stress, then develops into the final fault plane in the residual stress stage of the complete stress-strain relationship under triaxial conditions. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:293 / 305
页数:13
相关论文
共 22 条
  • [21] A new method of three-dimensional coronary artery reconstruction from X-ray angiography: Validation against a virtual phantom and multislice computed tomography
    Andriotis, Adamantios
    Zifan, Ali
    Gavaises, Manolis
    Liatsis, Panos
    Pantos, Ioannis
    Theodorakakos, Andreas
    Efstathopoulos, Efstathios P.
    Katritsis, Demosthenes
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (01) : 28 - 43
  • [22] Clinical value of low-dose three-dimensional reconstruction by multi-slice spiral computed tomography and by traditional X-ray in the diagnosis of distal radius epiphyseal injury in children
    Tang, Kai
    Wu, Fang
    Mao, Yongmin
    Shen, Jun
    Li, Yi
    Wang, Bang
    Zhang, Aiguo
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2024, 16 (07): : 3376 - 3384