Hierarchical Control of Parallel AC-DC Converter Interfaces for Hybrid Microgrids

被引:296
作者
Lu, Xiaonan [1 ]
Guerrero, Josep M. [2 ]
Sun, Kai [1 ]
Vasquez, Juan C. [2 ]
Teodorescu, Remus [2 ]
Huang, Lipei [3 ]
机构
[1] Tsinghua Univ, Beijing 100084, Peoples R China
[2] Aalborg Univ, Inst Energy Technol, DK-9220 Aalborg, Denmark
[3] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Hierarchical control; hybrid microgrid; parallel power electronics converter interface; CONTROL STRATEGY; OPERATION; IMPLEMENTATION; SYSTEMS;
D O I
10.1109/TSG.2013.2272327
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a hierarchical control system for parallel power electronics interfaces between ac bus and dc bus in a hybrid microgrid is presented. Both standalone and grid-connected operation modes in the dc side of the microgrid are analyzed. Concretely, a three-level hierarchical control system is implemented. In the primary control level, the decentralized control is realized by using the droop method. Local ac current proportional-resonant controller and dc voltage proportional-integral controller are employed. When the local load is connected to the dc bus, dc droop control is applied to obtain equal or proportional dc load current sharing. The common secondary control level is designed to eliminate the dc bus voltage deviation produced by the droop control, with dc bus voltage in the hybrid microgrid boosted to an acceptable range. After guaranteeing the performance of the dc side standalone operation by means of the primary and secondary control levels, the tertiary control level is thereafter employed to perform the connection to an external dc system. Meanwhile, the impact of the bandwidth of the secondary and tertiary control levels is discussed. The closed-loop model including all the three control levels is developed in order to adjust the main control parameters and study the system stability. Experimental results of a kW parallel ac-dc converter system have shown satisfactory realization of the designed system.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 31 条
[1]   Distributed Control to Ensure Proportional Load Sharing and Improve Voltage Regulation in Low-Voltage DC Microgrids [J].
Anand, Sandeep ;
Fernandes, Baylon G. ;
Guerrero, Josep M. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (04) :1900-1913
[2]   The influence of load impedance, line length, and branches on underground cable power-line communications (PLC) systems [J].
Anatory, Justinian ;
Theethayi, Nelson ;
Thottappillil, Rajeev ;
Kissaka, M. M. ;
Mvungi, N. H. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) :180-187
[3]  
[Anonymous], 2002, TECH REP
[4]   A Flexible Control Strategy for Grid-Connected and Islanded Microgrids With Enhanced Stability Using Nonlinear Microgrid Stabilizer [J].
Ashabani, Seyed Mahdi ;
Mohamed, Yasser Abdel-Rady I. .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (03) :1291-1301
[5]   Power electronics as efficient interface in dispersed power generation systems [J].
Blaabjerg, F ;
Chen, Z ;
Kjaer, SB .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (05) :1184-1194
[6]  
Bossanyi E., 2000, WIND ENERGY HANDBOOK
[7]  
Chia-Tse Lee, 2009, Proceedings of the 2009 IEEE Energy Conversion Congress and Exposition. ECCE 2009, P2022, DOI 10.1109/ECCE.2009.5316407
[8]   Modes of Operation and System-Level Control of Single-Phase Bidirectional PWM Converter for Microgrid Systems [J].
Dong, Dong ;
Thacker, Timothy ;
Cvetkovic, Igor ;
Burgos, Rolando ;
Boroyevich, Dushan ;
Wang, Fred ;
Skutt, Glenn .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (01) :93-104
[9]   Control of distributed uninterruptible power supply systems [J].
Guerrero, Josep M. ;
Hang, Lijun ;
Uceda, Javier .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (08) :2845-2859
[10]   Hierarchical Control of Droop-Controlled AC and DC Microgrids-A General Approach Toward Standardization [J].
Guerrero, Josep M. ;
Vasquez, Juan C. ;
Matas, Jose ;
Garci de Vicuna, Luis ;
Castilla, Miguel .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (01) :158-172