Digital Notch Filter based Active Damping for LCL Filters

被引:0
作者
Yao, Wenli [1 ]
Yang, Yongheng [2 ]
Zhang, Xiaobin [1 ]
Blaabjerg, Frede [2 ]
机构
[1] Northwestern Polytech Univ, Sch Automat, 127 Youyi West Rd, Xian 710072, Shaanxi, Peoples R China
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
来源
2015 THIRTIETH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2015) | 2015年
关键词
DESIGN;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
LCL filters are widely used in Pulse Width Modulation (PWM) inverters. However, it also introduces a pair of unstable resonant poles that may challenge the controller stability. The passive damping is a convenient possibility to tackle the resonance problem at the cost of system overall efficiency. In contrast, the active damping does not require any dissipation elements, and thus has become of increasing interest. As a result, a vast of active damping solutions have been reported, among which multi-loop control systems and additional sensors are necessary, leading to increased cost and complexity. In this paper, a notch filter based active damping without the requirement of additional sensors is proposed, where the inverter current is employed as the feedback variable. Firstly, a design method of the notch filter for active damping is presented. The entire system stability has then been investigated, which has revealed that negative variations of the resonant frequency can seriously affect the system stability. In order to make the controller more robust against grid impedance variations, the notch filter frequency is thus designed smaller than the LCL filter resonant frequency, which is done in the z-domain. Simulations and experiments are carried out to verify the proposed active damping method. Both results have confirmed that the notch filter based active damping can ensure the entire system stability in the case of resonances with a good system performance.
引用
收藏
页码:2399 / 2406
页数:8
相关论文
共 50 条
[41]   Robustness Analysis of Active Damping Methods for an Inverter connected to the grid with an LCL-Filter [J].
Ricchiuto, D. ;
Liserre, M. ;
Kerekes, T. ;
Teodorescu, R. ;
Blaabjerg, F. .
2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, :2028-2035
[42]   Model-Based Active Damping Control for Three-Phase Voltage Source Inverters With LCL Filter [J].
Guzman, Ramon ;
Garcia de Vicuna, Luis ;
Morales, Javier ;
Castilla, Miguel ;
Miret, Jaume .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (07) :5637-5650
[43]   Active Damping based on Ackemann's Formula for a Three-Phase Voltage Source Inverter with LCL Filter [J].
Guzman, Ramon ;
Garcia de Vicuna, Luis ;
Morales, Javier ;
Momeneh, Arash ;
Miret, Janine ;
Torres-Martinez, Javier .
IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, :1217-1222
[44]   Two Degrees of Freedom Active Damping Technique for LCL Filter-Based Grid Connected PV Systems [J].
Hanif, Moin ;
Khadkikar, Vinod ;
Xiao, Weidong ;
Kirtley, James L., Jr. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (06) :2795-2803
[45]   A Comparative Study on HCC Method for Grid-Connected LCL Filter with Active Damping [J].
Singh, Jitendra Kumar ;
Behera, Ranjan Kumar .
2019 21ST EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE '19 ECCE EUROPE), 2019,
[46]   A hybrid controller for PWM active rectifiers based LCL filters [J].
Marzouki, Amira ;
Hamouda, Mahmoud ;
Fnaiech, Farhat .
COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2015, 34 (04) :1229-1251
[47]   Limitations of LCL Filter for Three-Phase Shunt Active Power Filters in Active Traction Substations [J].
Bitoleanu, A. ;
Popescu, Mihaela ;
Linca, M. .
2016 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2016, :665-670
[48]   Proportional Capacitor Current Feedback Based Active Damping Control for LCL-Filter Converters with Considerable Control Delay [J].
ZhijunMa ;
Zhou, Linyuan ;
Liu, Jinjun .
2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, :3110-3114
[49]   Robust Active Damping in LCL-Filter-Based Medium-Voltage Parallel Grid Inverters for Wind Turbines [J].
Pena-Alzola, Rafael ;
Roldan-Perez, Javier ;
Bueno, Emilio ;
Huerta, Francisco ;
Campos-Gaona, David ;
Liserre, Marco ;
Burt, Graeme .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (12) :10846-10857
[50]   Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters [J].
Pena-Alzola, Rafael ;
Liserre, Marco ;
Blaabjerg, Frede ;
Sebastian, Rafael ;
Dannehl, Jorg ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2642-2646