Feasibility of boron neutron capture therapy for malignant spinal tumors

被引:5
作者
Nakai, Kei [1 ]
Kumada, Hiroaki [2 ]
Yamamoto, Tetsuya [1 ]
Tsurubuchi, Takao [1 ]
Zaboronok, Alexander [1 ]
Matsumura, Akira [1 ]
机构
[1] Univ Tsukuba, Grad Sch Comprehens Human Sci, Inst Clin Med, Dept Neurosurg, Tsukuba, Ibaraki 3058575, Japan
[2] Japan Atom Energy Agcy, Tokai Res & Dev Ctr, Tokai, Ibaraki, Japan
关键词
Feasible; BNCT; Spinal tumor; JCDS;
D O I
10.1016/j.apradiso.2009.03.089
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Treatment of malignant spinal cord tumors is currently ineffective. The characteristics of the spine are its seriality, small volume, and vulnerability: severe QOL impairment can be brought about by small neuronal damage. The present study aimed to investigate the feasibility of BNCT as a tumor-selective charged particle therapy for spinal cord tumors from the viewpoint of protecting the normal spine. A previous report suggested the tolerance dose of the spinal cord was 13.8 Gy-Eq for radiation myelopathy: a dose as high as 11 Gy-Eq demonstrated no spinal cord damage in an experimental animal model. We calculated the tumor dose and the normal spinal cord dose on a virtual model of a spinal cord tumor patient with a JAEA computational dosimetry system (JCDS) treatment planning system. The present study made use of boronophenylalanine (BPA). In these calculations, conditions were set as follows: tumor/normal (T/N) ratio of 3.5, blood boron concentration of 12 ppm, tumor boron concentration of 42 ppm, and relative biological effectiveness (RBE) values for tumor and normal spinal cord of 3.8 and 1.35, respectively. We examined how to optimize neutron irradiation by changing the beam direction and number. In our theoretical example, simple opposed two-field irradiation achieved 28.0 Gy-Eq as a minimum tumor dose and 7.3 Gy-Eq as a maximum normal spinal dose. The BNCT for the spinal cord tumor was therefore feasible when a sufficient T/N ratio could be achieved. The use of F-BPA PET imaging for spinal tumor patients is supported by this study. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S43 / S46
页数:4
相关论文
共 50 条
[21]   The effects of boron neutron capture therapy on liver tumors and normal hepatocytes in mice [J].
Suzuki, M ;
Masunaga, S ;
Kinashi, Y ;
Takagaki, M ;
Sakurai, Y ;
Kobayashi, T ;
Ono, K .
JAPANESE JOURNAL OF CANCER RESEARCH, 2000, 91 (10) :1058-1064
[22]   Boron neutron capture therapy for glioblastoma [J].
Yamamoto, Tetsuya ;
Nakai, Kei ;
Matsumura, Akira .
CANCER LETTERS, 2008, 262 (02) :143-152
[23]   Boron carbide nanoparticles for boron neutron capture therapy [J].
Xu, Shiwei ;
Yu, Ying ;
Zhang, Boyu ;
Zhu, Kejia ;
Cheng, Yuan ;
Zhang, Tao .
RSC ADVANCES, 2025, 15 (14) :10717-10730
[24]   The role of boron MRI in boron neutron capture therapy [J].
George W. Kabalka ;
Chao Tang ;
Peter Bendel .
Journal of Neuro-Oncology, 1997, 33 :153-161
[25]   The role of boron MRI in boron neutron capture therapy [J].
Kabalka, GW ;
Tang, C ;
Bendel, P .
JOURNAL OF NEURO-ONCOLOGY, 1997, 33 (1-2) :153-161
[26]   Fast Neutron Beams for Boron Neutron Capture Therapy? [J].
Wolber, Gerd .
Zeitschrift fur Medizinische Physik, 2004, 14 (01) :55-63
[27]   Feasibility study on pinhole camera system for online dosimetry in boron neutron capture therapy [J].
Katabuchi, Tatsuya ;
Hales, Brian ;
Hayashizaki, Noriyosu ;
Igashira, Masayuki ;
Khan, Zareen ;
Kobayashi, Tooru ;
Matsuhashi, Taihei ;
Miyazaki, Koichi ;
Ogawa, Koichi ;
Terada, Kazushi .
APPLIED RADIATION AND ISOTOPES, 2014, 88 :139-142
[28]   Feasibility study of SPECT system for online dosimetry imaging in boron neutron capture therapy [J].
Hales, B. ;
Katabuchi, T. ;
Hayashizaki, N. ;
Terada, K. ;
Igashira, M. ;
Kobayashi, T. .
APPLIED RADIATION AND ISOTOPES, 2014, 88 :167-170
[29]   Block copolymer-boron cluster conjugate for effective boron neutron capture therapy of solid tumors [J].
Mi, Peng ;
Yanagie, Hironobu ;
Dewi, Novriana ;
Yen, Hung-Chi ;
Liu, Xueying ;
Suzuki, Minoru ;
Sakurai, Yoshinori ;
Ono, Koji ;
Takahashi, Hiroyuki ;
Cabral, Horacio ;
Kataoka, Kazunori ;
Nishiyama, Nobuhiro .
JOURNAL OF CONTROLLED RELEASE, 2017, 254 :1-9
[30]   A study on the optimum fast neutron flux for Boron Neutron Capture Therapy of deep-seated tumors [J].
Rasouli, Fatemeh S. ;
Masoudi, S. Farhad .
APPLIED RADIATION AND ISOTOPES, 2015, 96 :45-51